4.1.5
Decision Block
The Decision block evaluates a Boolean expression as true/false. The expression may 
consist of one or more bits. The Decision block has one entry point and two exit points 
(Yes/No), based on the Boolean decision. Use the “Decision Block” dialog box to select the 
bit(s) to be evaluated, which are of these types:
Flag
Input
Output
Keypad key
Timer/Counter
High-Speed Counter
The AND and OR “Operator” in the dialog box permits adding a second Boolean 
condition to the expression. Expressions are evaluated from top-down. nanoLC 
supports one or two Boolean conditions in one Decision block. Double-click the 
Decision block to edit its expression. This displays the “Decision Block... Configu-
ration” tab (see Figure 4-6).
Figure 4-6
“Decision Block... Configuration” tab
To perform a non-Boolean comparison, use the Compare block (see “Compare Block” on 