3.3 Simulation of a circuit program 
LOGO!Soft Comfort Online Help 
Operating Instructions, 06/2014 
147
 
3.3.8 
Alternative operation 
You can click directly the inputs to switch them on or off.  
 
3.3.9 
Controlling the simulation time 
The simulation mode of LOGO!Soft Comfort allows you to test your circuit program on a 
timed basis, or over a specific number of cycles. You can even modify the time of day to test 
timer operations in your circuit program. See the time control (Page 35) section in the 
simulation toolbar topic for more information on the capabilities you have in simulation mode.    
3.3.10 
Simulating network communication (0BA7 and 0BA8 only) 
In simulation mode, LOGO!Soft Comfort creates a virtual network simulation group in the 
background to support network simulation. You can put one or more circuit programs into 
this group. You can create only one simulation group at a time and the IP address of each 
circuit program in a group must be unique. The following figure shows three circuit programs 
in a simulation group. 
 
After you start simulation, the simulation toolbar contains a toggle button, which is available 
only after you configure the Ethernet connection information. 
 
 If you click the network simulation button, LOGO!Soft Comfort displays the circuit programs 
in the simulation group. The following figure shows a circuit program that is being simulated.