User interface
2.8 Menu bar
LOGO!Soft Comfort Online Help
Operating Instructions, 06/2014
Operating Instructions, 06/2014
73
Transfer through Dynamic DNS (0BA7 and later only)
If you select Dynamic DNS for the communication, you can enter a known URL address or
click the arrow in the URL textbox to recall an URL address you entered before:
You must configure your router in order to access the LOGO! Base Module through dynamic
DNS. Make sure you have completed the following settings before connection:
● The remote LOGO! Base Module has a valid dynamic DNS account for routing.
● The local router has added the dynamic DNS of the remote LOGO! Base Module as a
● The remote LOGO! Base Module has a valid dynamic DNS account for routing.
● The local router has added the dynamic DNS of the remote LOGO! Base Module as a
HTTP virtual server.
Note
LOGO! 0BA8 devices communicate with a remote LOGO! Base Module in TCP protocol
LOGO! 0BA8 devices communicate with a remote LOGO! Base Module in TCP protocol
through private port 8080.