Техническая Спецификация для Lappkabel 00231138 ÖLFLEX® SOLAR XLS Solar Photovoltaic PV Cable, 1 x 6 mm², Black, White Sheath 00231138
Модели
00231138
U.I. Lapp
GmbH
DATA SHEET
ÖLFLEX
®
SOLAR XLS-R
DB 0023100EN
valid from: 01.10.2011
Originator: H. Hörtnagl / PCM
approved: PDC
Document:
DB0023100EN
page 1 of 2
All deviations from this specification are subject to explicit consent of U.I. Lapp GmbH. All rights reserved acc. to DIN 34.
PD 0019/2.1_11.09EN
1. Application
ÖLFLEX
®
SOLAR XLS-R cables are weather-, abrasion- and UV-resistant photovoltaic cables. These cross-linked, halogen
free and double insulated solar cables are suitable for permanent outdoor use and especially for the interconnection of
grounded and ungrounded photovoltaic power systems. They are applicable for the connection of solar panels among them-
selves and as extension cable between the individual module strings or the DC/AC inverter.
grounded and ungrounded photovoltaic power systems. They are applicable for the connection of solar panels among them-
selves and as extension cable between the individual module strings or the DC/AC inverter.
2. Cable design
1. Conductor:
Fine wire strands of tinned copper according to IEC 60228, Class 5
2. Core insulation:
Temperature resistant and halogen free polyolefine co-polymer,
electron beam cross-linked
Colour: white, red or blue
3. Outer sheath:
Flame retardant, weather resistant and halogen free polyolefin co-polymer,
electron beam cross-linked,
Outer sheath colour: black
3. Electrical properties
Rated voltage U
0
/U acc. IEC
AC 600/1000 V
DC 900/1500 V
DC 900/1500 V
Max. permissible operating voltage
DC 1800 V (conductor/conductor, non earthed system)
Test voltage
AC 6,5 kV
4. Thermal properties
Temperature range
fixed installation: -40 °C up to +100 °C
(max. conductor temperature according to IEC 60216)
(max. conductor temperature according to IEC 60216)
High temperature pressure resistance
according EN 60811-3-1
Damp heat resistance
according EN 60068-2-78 at 85% humidity
5. Mechanical properties
Minimum bending radius
occasional flexing: 15 x cable diameter
fixed installation: 5 x cable diameter
Dynamic penetration resistance
according DKE requirement specification PV1-F AK 411.2.3 Annex F
Notch propagation resistance
according DKE requirement specification PV1-F AK 411.2.3 Annex G
Tensile strength and elongation
of insulation and jacket
according EN 60811