Техническая Спецификация для Buffalo NAS server 12 TB TeraStation 5400 Rack WD Red TS5400RWR1204-EU TS5400RWR1204-EU
Модели
TS5400RWR1204-EU
174
Chapter 12 Appendix
LCD Display
The LCD display can be cycled through different modes by pressing the display button on the front of the TeraStation.
Also, the items displayed can be configured at Management - Notifications - Front Panel Display Settings in Settings.
Also, the items displayed can be configured at Management - Notifications - Front Panel Display Settings in Settings.
Modes
LCD Message
Description
Corrective Action
LINK SPEED
Note: When an
Ethernet cable
is connected
to LAN Port 2,
“LINK SPEED 2” is
displayed.
Note: When an
Ethernet cable
is connected
to LAN Port 2,
“LINK SPEED 2” is
displayed.
LINK SPEED
No LINK
No LINK
Not connected to network.
Connect an Ethernet
cable to the LAN port.
LINK SPEED
10 Mbps HALF
10 Mbps HALF
Connected at 10 Mbps half duplex.
-
LINK SPEED
10 Mbps FULL
10 Mbps FULL
Connected at 10 Mbps full duplex.
-
LINK SPEED
100 Mbps HALF
100 Mbps HALF
Connected at 100 Mbps half duplex.
-
LINK SPEED
100 MbpsFULL
100 MbpsFULL
Connected at 100 Mbps full duplex.
-
LINK SPEED
1000 Mbps
1000 Mbps
Connected at 1000 Mbps full duplex.
-
Hostname / IP
Address
TS-xx xxx
192.168.11.150
192.168.11.150
Displays the hostname and IP address. At the
end of the IP address, F (fixed IP address) or D
(IP address automatically acquired from a DHCP
server) is displayed.
Note: When an Ethernet cable is connected to LAN
port 2, “NETWORK2” is displayed in the hostname
section.
Note: When an Ethernet cable is connected to LAN
port 2, “NETWORK2” is displayed in the hostname
section.
-
Calendar / Clock
DATE TIME
2012/1/1 11:11
2012/1/1 11:11
Displays the date and time set in the TeraStation.
-
Errors
LCD Message
Description
Corrective Action
BOOT FAIL
Hard drive not found.
Contact Buffalo technical support for
assistance.
SYSTEM Error E04
Can’t Load Krnl!
Can’t Load Krnl!
The firmware is corrupted.
Contact Buffalo technical support for
assistance.
UPS E10
Dependent Mode
Dependent Mode
The TeraStation is running on the UPS battery
due to a power outage. The system will now
be shut down safely.
Check that power is being supplied to the
UPS, and if there are no problems, turn on the
TeraStation.