Справочник Пользователя для QNAP TS-112

Скачать
Страница из 87
 
26 
 
Chapter 4. 
LED and Alarm Buzzer Specifications 
 
The LED indicators of the NAS indicate the system status and information. When the NAS is 
turned on, check the following items to make sure the system status is normal. Note that 
the following LED information is applicable only when users have properly installed the hard 
drive, and connected the NAS to the network and the power supply. 
LED 
Color 
LED Status 
Description 
System 
Status 
Red/ 
Green 
Flashes green 
and red 
alternately 
every 0.5 sec   
1.  The hard drive on the NAS is being 
formatted. 
2.  The NAS is being initialized. 
3.  The system firmware is being updated. 
4.  RAID rebuilding is in process. 
5.  Online RAID Capacity Expansion is in 
process. 
6.  Online RAID Level Migration is in process. 
Red 
1.  The hard drive is invalid. 
2.  The disk volume has reached its full 
capacity. 
3.  The disk volume is going to be full. 
4.  The system fan is out of function. 
5.  An error occurs when accessing 
(read/write) the disk data. 
6.  A bad sector is detected on the hard 
drive. 
7.  The NAS is in degraded read-only mode 
(2 member drives fail in a RAID 5 or RAID 
6 configuration, the disk data can still be 
read). 
8.  Hardware self-test error. 
Flashes red 
every 0.5 sec   
The NAS is in degraded mode (one member 
drive fails in RAID 1, RAID 5 or RAID 6 
configuration). 
Flashes green 
every 0.5 sec 
1.  The NAS is starting up. 
2.  The NAS is not configured. 
3.  A hard disk drive is not formatted. 
Flashes green 
every 2 
seconds 
The NAS is in S3 sleep mode
1
Green 
The NAS is ready. 
                                           
1
  This feature is only available on certain NAS models. Please refer to the product specification table 
for details at www.qnap.com.