INSTRUCTIONS FOR UPLOAD FROM LOCAL DIRECTORY 
 
1.  Download the firmware file from Grandstream web site 
2.  Unzip it and copy the file in to a folder in your PC 
3.  From  the  DP715  web  interface  (Advanced  Settings  page)  you  can  browse  your  hard  drive  and 
select the folder where you previously saved the file. 
4. 
Click “Upload Firmware” and wait few minutes until the new program is loaded. 
 
Note: Always check the status page to see that the program version has changed. 
 
INSTRUCTIONS FOR LOCAL FIRMWARE UPGRADE USING TFTP SERVER 
 
1.  Unzip the file and put all of them under the root directory of the TFTP server.  
2.  Put the PC running the TFTP server and the DP715 device in the same LAN segment. 
3.  Please  go  to  File  ->  Configure  ->  Security  to  change  the  TFTP  server's  default  setting  from 
"Receive Only" to "Transmit Only" for the firmware upgrade.  
4. 
Start the TFTP server, in the phone’s web configuration page 
5.  Configure the Firmware Server Path with the IP address of the PC 
6.  Update the change and reboot the unit  
 
End users can also choose to download the free HTTP server from http://httpd.apache.org/ or use Microsoft 
IIS web server. 
 
CONFIGURATION FILE DOWNLOAD 
 
Grandstream  SIP  Device  can  be  configured  via  Web  Interface  as  well  as  via  Configuration  File  through 
TFTP or HTTP/HTTPS. “Config Server Path” is the TFTP or HTTP/HTTPS server path for configuration file. 
It needs to be set to a valid URL, either in FQDN or IP address format. The “Config Server Path” can be 
same or different from the “Firmware Server Path”. 
 
A  configuration  parameter  is  associated  with  each  particular  field  in  the  web  configuration  page.    A 
parameter  consists  of  a  Capital  letter  P  and  1  to  3  (Could  be  extended  to  4  in  the  future)  digit  numeric 
numbers.    i.e.,  P2  is  associated  with 
“Admin  Password”  in  the  ADVANCED  SETTINGS  page.    For  a 
detailed parameter list, please refer to the corresponding firmware release configuration template. 
  
When  a  Grandstream  device  boots  up  or  reboots,  it  will  issue  a  request  for  a  configuration  file 
“cfgxxxxxxxxxxxx”,  where  “xxxxxxxxxxxx”  is  the  MAC  address  of  the  device,  i.e.,  “cfg000b820102ab”.    In 
addition,  device  will  also  requests  a  XML  configuration  file  “cfgxxxxxxxxxxxx.xml”.  If  the  download  of 
“cfgxxxxxxxxxxxx.xml”  is  not  successful,  the  provision  program  will  issue  a  request  for  a  generic 
configuration file “cfg.xml”. Configuration file name should be in lower case letters. 
 
For more details on XML provisioning, please refer to: 
 
FIRMWARE AND CONFIGURATION FILE PREFIX AND POSTFIX 
Firmware  Prefix  and  Postfix  allows  device  to  download  the  firmware  name  with  the  matching  Prefix  and 
Postfix.  This makes it the possible to store ALL of the firmware with different version in one single directory.