Техническая Спецификация для MEAN WELL CLG-60-12

Скачать
Страница из 3
SPECIFICATION
MODEL
CLG-60-12
CLG-60-15
CLG-60-20
CLG-60-24
CLG-60-27
CLG-60-36
CLG-60-48
DC VOLTAGE
CURRENT RANGE          
RATED POWER               
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION      
LOAD REGULATION      
 
SETUP TIME
VOLTAGE RANGE          
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(
)
Typ.
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT   
SHORT CIRCUIT      
OVER VOLTAGE           
 
OVER TEMPERATURE
12V
15V
20V
24V
27V
36V
48V
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
0 ~ 2.3A
0 ~ 1.7A
0 ~ 1.3A
60W
60W
60W
60W
62.1W
61.2W
62.4W
2Vp-p
2.4Vp-p
1.8Vp-p
2.7Vp-p
2.7Vp-p
3.6Vp-p
4.6Vp-p
±10%
Fixed can be modified between the range above
Fixed. Can be modified between 3% ~ -25% rated output current
±3.0%
±5.0%
500ms / 230VAC    3000ms / 115VAC at full load
90 ~ 295VAC          127 ~ 417VDC
47 ~ 63Hz
PF>0.94/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
85%
86%
87.5%
87%
88%
89%
89%
13.8 ~ 16V
17.5 ~ 21V
23 ~ 28V
28 ~ 32V
31 ~ 35V
41 ~ 46V
54 ~ 60V
COLD START 35A(twidth=45 s measured at 50% Ipeak) at 230VAC
μ
<0.75mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
-30 ~ +70
 
℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
 (0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes
495.7Khrs min.      MIL-HDBK-217F (25
)
195.6*61.5*38.8mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Please refer to "DRIVING METHODS OF LED MODULE".
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the 
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently 
      connected to the mains.
0.86Kg; 16pcs/14.8Kg/0.54CUFT
Protection type : Shut down o/p voltage, re-power on to recover
60W Single Output LED Power Supply
Universal AC input / Full range (up to 295VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature 
Cooling by free air convection
IP67 design for indoor or outdoor installations
Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications 
(Note.2)
Compliance to worldwide safety regulations for lighting 
Suitable for dry / damp / wet locations
3 years warranty
High efficiency up to 89%
 Features :
C L G - 6 0  
s e r i e s
RIPPLE & NOISE (max.)  
Note.2
VOLTAGE TOLERANCE  
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
File Name:CLG-60-SPEC   2014-03-26
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
SAFETY STANDARDS
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (≧75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV),  criteria A
10.5 ~ 15V
14 ~ 20V
16.8 ~ 24V
18.9 ~ 27V
25.2 ~ 36V
33.6 ~ 48V
8.4 ~ 12V
RATED CURRENT
5A
4A
3A
2.5A
2.3A
1.7A
1.3A
CONSTANT CURRENT REGION 
Note.5
11.5 ~ 13V
14.5 ~ 16.2V
19.5 ~ 22V
24 ~ 26V
25 ~ 30V
32.5 ~ 39V
43.6 ~ 51.8V
EMC IMMUNITY
EMC EMISSION
IP67
..
( for 48V only)
( except for 48V )
F
M
M
110
LPS
SELV
0.8A/115VAC          0.4A/230VAC          0.3A/277VAC
UL879, UL8750, UL1310, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V),
CSA C22.2 No. 250.0-08(except for 48V), CSA C22.2 No. 207-M89(except for 48V), IP67, J61347-1, J61347-2-13 approved