Техническая Спецификация для MEAN WELL CLG-60-12
SPECIFICATION
MODEL
CLG-60-12
CLG-60-15
CLG-60-20
CLG-60-24
CLG-60-27
CLG-60-36
CLG-60-48
DC VOLTAGE
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(
)
Typ.
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
12V
15V
20V
24V
27V
36V
48V
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
0 ~ 2.3A
0 ~ 1.7A
0 ~ 1.3A
60W
60W
60W
60W
62.1W
61.2W
62.4W
2Vp-p
2.4Vp-p
1.8Vp-p
2.7Vp-p
2.7Vp-p
3.6Vp-p
4.6Vp-p
±10%
Fixed can be modified between the range above
Fixed. Can be modified between 3% ~ -25% rated output current
±3.0%
±5.0%
500ms / 230VAC 3000ms / 115VAC at full load
90 ~ 295VAC 127 ~ 417VDC
47 ~ 63Hz
PF>0.94/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
85%
86%
87.5%
87%
88%
89%
89%
13.8 ~ 16V
17.5 ~ 21V
23 ~ 28V
28 ~ 32V
31 ~ 35V
41 ~ 46V
54 ~ 60V
COLD START 35A(twidth=45 s measured at 50% Ipeak) at 230VAC
μ
<0.75mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
-30 ~ +70
℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
℃
±
℃
℃
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
495.7Khrs min. MIL-HDBK-217F (25
)
℃
195.6*61.5*38.8mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Please refer to "DRIVING METHODS OF LED MODULE".
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
0.86Kg; 16pcs/14.8Kg/0.54CUFT
Protection type : Shut down o/p voltage, re-power on to recover
60W Single Output LED Power Supply
‧
Universal AC input / Full range (up to 295VAC)
‧
Built-in active PFC function
‧
‧
Protections: Short circuit / Over current / Over voltage / Over temperature
‧
Cooling by free air convection
‧
IP67 design for indoor or outdoor installations
‧
Class 2 power unit
‧
Pass LPS
‧
100% full load burn-in test
‧
High reliability
‧
Suitable for LED lighting and moving sign applications
(Note.2)
‧
Compliance to worldwide safety regulations for lighting
‧
Suitable for dry / damp / wet locations
‧
3 years warranty
High efficiency up to 89%
■
Features :
C L G - 6 0
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
File Name:CLG-60-SPEC 2014-03-26
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
SAFETY STANDARDS
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (≧75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A
10.5 ~ 15V
14 ~ 20V
16.8 ~ 24V
18.9 ~ 27V
25.2 ~ 36V
33.6 ~ 48V
8.4 ~ 12V
RATED CURRENT
5A
4A
3A
2.5A
2.3A
1.7A
1.3A
CONSTANT CURRENT REGION
Note.5
11.5 ~ 13V
14.5 ~ 16.2V
19.5 ~ 22V
24 ~ 26V
25 ~ 30V
32.5 ~ 39V
43.6 ~ 51.8V
EMC IMMUNITY
EMC EMISSION
IP67
..
( for 48V only)
( except for 48V )
F
M
M
110
LPS
SELV
0.8A/115VAC 0.4A/230VAC 0.3A/277VAC
UL879, UL8750, UL1310, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V),
CSA C22.2 No. 250.0-08(except for 48V), CSA C22.2 No. 207-M89(except for 48V), IP67, J61347-1, J61347-2-13 approved