Program description: Telemetry menu
wish to use the RX CURVE option - then two curves 
must be set:
RX CURVE
      TYPE :   A
CURVE1 CH  :  02
      TYPE :   A
CURVE2 CH  :  05
      TYPE :   B
CURVE3 CH  :  04
5CH FUNCTION:SERVO
If you ignored this, the left and right ailerons would 
exhibit different control characteristics.
The RX CURVE function can be used to manage the 
control characteristics for up to three servos:
CURVE 1, 2 or 3 CH
• 
Select the desired control channel (INPUT CH) for 
the fi rst servo.
The following setting in TYPE only affects the chan-
nel you select at this point.
TYPE
Select the servo curve:
A: EXPO = -100% and DUAL RATE = 125% 
The servo responds slowly to stick movements 
around the neutral position, but the curve becomes 
steeper with increasing control travel.
B: Linear setting 
The servo follows the stick movement with a linear 
response.
C: EXPO = +100% and DUAL RATE = 70%
The servo responds slowly to stick movements 
around the neutral position, but the curve becomes 
steeper with increasing control travel.
Note:
The control characteristics programmed at this point 
also affect mapped receiver outputs.
RX SERVO TEST
RX SERVO TEST
ALL–MIN  : 1000sec
ALL–MAX  : 2000sec
ALARM VOLT : 3.8V
TEST     : STOP
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
Value
Explanation
Possible settings
ALL-MAX
Servo travel on 
the “+” side for all 
servo outputs in 
the servo test
1500 … 2000 μs
ALL-MIN
Servo travel on 
the “-” side for all 
servo outputs in 
the servo test
1500 … 1000 μs
TEST
Test procedure
START / STOP
ALARM 
VOLT
Alarm limit for the 
receiver low-
voltage warning
3,0 … 6,0 V
Default setting: 
3,8 V 
ALARM 
TEMP+
Alarm limit for 
excessive receiver 
temperature
50 … 80 °C
Default setting: 
70 °C
ALARM 
TEMP–
Alarm limit for 
excessively 
low receiver 
temperature
-20 … +10 °C
Default setting: 
-10 °C
CH OUTPUT 
TYPE
Channel sequence ONCE, SAME, 
SUMI, SUMO
ALL MAX (maximum servo travel)
In this line you can set the maximum servo travel for the 
servo test on the plus side of control travel.
2000 μs corresponds to full travel, 1500 μs corresponds 
to the neutral position.
ALL MIN (minimum servo travel)
In this line you can set the maximum servo travel for the 
servo test on the minus side of control travel.
1000 μs corresponds to full travel, 1500 μs corresponds 
to the neutral position.
TEST
In this line you can start and stop the receiver’s integral 
servo test.
Press the 
INC+DEC
 button to activate the input fi eld:
RX SERVO TEST
ALL–MIN  : 1000sec
ALL–MAX  : 2000sec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
TEST     : 
STOP
Now select 
START
 with one of the arrow buttons of the 
right-hand four-way button:
RX SERVO TEST
ALL–MIN  : 1000sec
ALL–MAX  : 2000sec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
TEST     : 
START
Press the 
INC+DEC
 button to start the test-run. The 
input fi eld now reverts from highlighted to “normal”: