Техническая Спецификация для Eurolite N-19 black with ON/OFF 5170195A

Модели
5170195A
Скачать
Страница из 18
00056356.DOC, Version 2.2
16/18
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
OPERATION
Connect the remote control with the Remote Control-socket.Switch the device on via the power switch.
After a certain warm-up time, the device is ready to operate. Then
the stand-by lamp of the remote control lights up. By operating the
smoke switch on the remote control the smoke emission starts. It
may happen that the stand-by lamp turns off and the smoke
emission stops. In this case the device is heating up again and will
be ready to operate in approx. 1-2 min. This process guarantees an
appropriate vaporization temperature and the best smoke emission
possible. The temperature is regulated by a high quality thermostat.
CAUTION: The escape nozzle will heat up during operation. Therefore do not touch the nozzle until it
has cooled down completely.
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
Clean the escape nozzle frequently from smoke fluid residues. Clean out debris with vinegar and a pipe
cleaner, making sure that the hole is free of clogs.