Техническая Спецификация для Arnold Rak 36 m Heating Cable / 30-6106
Модели
30-6106
Installation
Instructions
Instructions
Heating Cable TWIN Series 61
Flexible Installation In Complex Room Shapes
Product Information
The TWIN series heating cables are supplied ready for connection, including a 3 m long connection cable
(cold conductor). They are available with a rated power of 30 W per meter.
The cables are manufactured to VDE standards DIN EN60335-2-96, DIN EN60335-1, and DIN EN 50366.
Approval: VDE (heating conductor).
The application areas detailed below are indoor floor temperature control and outdoor surface heating.
Type
Voltage
Power
Diameter
Rated
temperatur
limit
Connection
cable
Insulation
Minimum
Installation
spacing
61xx-30
230 V
30 W / lfm
5 mm
80° C
3x1,0 mm
2
FEP(Teflon®) /
Polyester / PVC
9 cm
Heating Cable Type 61xx-30, 30 W / rm, 5 mm
for indoor floor temperature control and outdoor surface heating
This heating cable can be embedded directly into the screed (min. 20 mm screed above the heating cable)
and is therefore especially suited for newly built properties in which the flooring has not been finished yet.
Depending on individual requirements, the heating performance range is 150 to 350 W/m
2
. For tiled floors up
to 200 W/m
2
can be used and for other flooring materials such as parquet, laminate, carpet or linoleum 160
W/m
2
should not be exceeded.
The heating cable is also used for outdoor surface heating, for example, for heating external stairs, entrance
areas, patios and driveways and for keeping them free of snow when required. Use as a roof or gutter
heating system is also possible.
The cable is not intended for embedding in bituminous mastic or reinforced concrete.
areas, patios and driveways and for keeping them free of snow when required. Use as a roof or gutter
heating system is also possible.
The cable is not intended for embedding in bituminous mastic or reinforced concrete.
GB