General notes 
The  timer  is  designed  only  for  230VAC  motors  in  roller 
shutter  and  sun  protection  facilities.  The  timer 
presupposes  adjusted  end  positions  of  the  motor.  The 
timer  fits  into  almost  all  standard  cover  frames.  The 
necessary cover frames can be ordered optionally. 
                         -------------- up button 
                        -------------- mode button 
                        -------------- down button 
                   
\
---------------------- reset button under 
                                  front panel 
Safety precautions 
  Please  note  that  the  control  requires  an  operating 
voltage of 230VAC, 50Hz. Please be sure to contact a 
professional electrician for the installation. 
  Please  make  sure  operating  voltage  is  switched  OFF 
when work/adjustments need to be done on windows or 
roller shutters controlled by the timer. 
  The control is intended only for its  designated  use (as 
described in the operating instructions). Adjustments or 
modifications  may  not  be  made,  otherwise  any  claims 
of warranty become null and void. 
  Check the control for any signs of damage immediately 
after unpacking. If there is damage due to shipping and 
notify the supplier immediately. 
Do not start up the control in case of any damage ! 
  If safe operation of the control can not be guaranteed, 
the  timer  must  be  turned  off  immediately  and  second 
protected  against  unintentional  operation.  The  same 
applies for work  on windows  or roller shutters that  are 
operated by this control. 
Functions of the Programmable Time Switch 
UP button 
UP motion command 2,5 min. or STOP when motor is 
running 
DOWN button 
DOWN motion command 2,5 min. or STOP when 
motor is running 
MODE button <2 sec  Change of mode ( auto / manual / random ) or STOP 
when motor is running 
MODE button >2 sec  Activation of program mode or STOP when motor is 
running 
Reset button  2 sec 
(under front panel) 
Reset, manufacturer's default setting                                
(UP 7:00, DOWN 21:00, Time 12:00 ) 
Optional function modes 
By pressing the mode button the optional function modes can be adjusted so 
they can be seen one after the other.  
You have 3 possible modes to choose from : 
AUTO   =  Automatic  ( daily program ) 
      =  Manual control
      =  Random = automatic + random time from 1 - 31 minutes
In the automatic mode the roller shutters are automatically opened or closed  
at the programmed switching times. 
In each mode of operation the motor can be controlled and stopped 
immediately without delay with the UP and DOWN buttons. 
If the random mode is activated the programmed switching 
commands are set back each day at random by 1 - 31 minutes. 
Programming  
Press MODE button  
>2 sec 
The time (hour indication) flashes and 

 - symbol is 
shown. 
Set the 
time with the 
UP or DOWN button 
By holding down the UP or DOWN button the time 
display runs faster. The mode button changes from 
hour to minutes setting. 
Press MODE button 
shortly 
The current switching time UP, „P“ symbol and            
5
 symbol are indicated.  
Set the switching time 
“UP” with the UP or 
DOWN button 
By holding down the UP or DOWN button the time 
display runs faster. The mode button changes from 
the hour to the minutes setting. 
Press MODE button 
shortly 
The current switching time DOWN, „P“ symbol and      
6
 symbol are indicated. 
Set the switching time 
“DOWN” with the UP or 
DOWN button 
By holding down the UP or DOWN button the time 
display runs faster. The mode button changes from 
the hour to the minutes setting. 
Press MODE button 
shortly 
End of the programming mode. The time and the 
current mode are displayed. 
Technical data 
Supply voltage :         230 V, 50 Hz +/- 10% 
Stand by :                < 1 W 
Output (UP/DOWN) :     230 V, 50 Hz (not potential free) 
Switching capacity :       250 V, 50 Hz, 5A, cos  = 1 
Running time :           2,5 min. 
Protection class :        IP20 
Safety class :            II 
Ambient temperature :    -5 … +45 °C 
Switch-over-delay :      min. 0,5 sec. 
Power reserve :          approx. 2 min. 
Conformity mark :        CE, RoHS 
All technical data is subject to change ! 
                               
39/07
Connection diagram
mains 230V