INSTALLATION
Tumble  dryers  are  supplied  to  operate  at  a 
voltage of 220-240V, 50 Hz single phase. Check 
that the supply circuit is rated to at least 10A.
Electricity can be extremely dangerous.
This appliance must be earthed.
The  socket  outlet  and  the  plug  on  the 
appliance must be of the same type.
Do  not  use  multiple  adapters  and/or 
extension leads.
The  plug  should  be  accessible  for 
disconnection after the appliance has been 
installed.
The  wires  in  the  mains  lead  are  coloured  in 
accordance with the following codes:
Blue
NEUTRAL
Brown
LIVE
Green and Yellow                EARTH
Electrical Requirements
    If  the  mains  cord  on  this  appliance  is 
damaged, it must be replaced by a special cord 
which  is  ONLY  obtainable  from  the  spares 
service.  It  must  be  installed  by  a  competent 
person.
        You may be charged for a service call if a 
problem  with  your  machine  is  caused  by 
incorrect installation.
Once the machine is in 
place  the  feet  should 
be  adjusted  to  ensure 
that  the  machine  is 
level.
Adjusting the Feet
Adequate  ventilation  must  be  provided  in  the 
room  where  the  tumble  dryer  is  located  to 
prevent  gases  from  appliances  burning  other 
fuels, including open fires, being drawn into the 
room during operation of the tumble dryer.
●  Exhaust air must not be discharged into a flue 
which  is  used  for  exhausting  fumes  from 
appliances burning gas or other fuels.
● Check regularly that the air flowing through 
the dryer is not restricted.
● Check  the  fluff  filter  after  use,  and  clean,  if 
necessary.
●The inlet and outlets should be kept free from 
obstructions.  To  ensure  adequate  ventilation 
the space between the bottom of the machine 
and  the  floor  must  not  be  obstructed.  There 
should be a gap of at least 12mm between the 
machine and any obstructions.
● Prevent items from falling or collecting behind 
the dryer as these may obstruct the air inlet and 
outlet.
● NEVER install the dryer up against curtains.
VENTILATION
          Do not plug the machine in and switch it 
on  at  the  mains  until  the  installation  is 
completed.For  your  safety,  this  dryer  must  be 
correctly  installed.  If  there  is  any  doubt  about 
installation, call Customer Care for advice.
Air Outlets
Air Outlets in the Base 
Air Inlent Vents
             
Do not install the product in a room where 
there is a risk of frost occurring. At temperature 
around  freezing  point  the  product  may  not  be 
able  to  operate  properly:  there  is  a  risk  of 
damage if the water is allowed to freeze in the 
hydraulic circuit (valves, hoses, pumps). 
For a better product performance the ambient 
room temperature must be between +2°C and 
+35°C.
EN