Справочник Пользователя для Lorex L15LD400

Скачать
Страница из 59
39
Configuration
ALARM SETUP 
1. CHANNEL - Select a channel for the setup.        
2. ALARM INPUT - Set up the Alarm Input type. 
• NORMALLY CLOSED - The Alarm is triggered 
when the circuit is closed (ON). 
• NORMALLY OPEN - The Alarm is triggered 
when the circuit is opened (OFF).        
3. DURATION - Setup for the post-alarm recording 
duration, and the alarm output duration. The 
duration setting is applied to both functions. The 
setting range is from 1 second to 99 seconds. 
NOTE: Alarm output can be triggered by alarm input 
and video loss. Motion cannot trigger an alarm 
output.
INTERVAL SETUP 
1. SEQUENCE SCREEN - Full Screen Sequence 
Interval setup (1~99 SEC). 
2. PIP SCREEN - Picture in Picture- setup for the 
sub-picture’s sequence interval (1~99 SEC). 
3. EVENT UPDATE - The Event Update Time 
prevents the system from recording the event logs 
from the same event. The event types include A
• Alarm
• Motion 
• Video loss. 
When an event is triggered, it is possible that the 
same event type continues to be triggered for a 
period of time (i.e. Motion starts, then stops for a 
short period, then starts again). 
With the Event Update Time setting, whenever 
there is an event, the system records the starting 
time and information of the event in the Event Log, 
and ignores the following events within the duration 
set in the Event update time. The setting range of 
the Event Update time is from 10 seconds to 990 
seconds.