3.7  ANTI-PASS BACK – 1833, 1835, 1837 only with APB CHIP SET 
The programming steps below will allow you to set up and program some basic functions for the anti-
pass back feature.  However, you must set up the IN and OUT relay programming table in the 
Remote Account Manager software, version 5.6.  Anti-Pass Back tables cannot be set from the 
keypad.  Refer to manual 1835-066. 
 
3.7.1 
Programming the Anti-Pass Back Mode 
Anti-Pass Back (APB) can be set to operate in one of three different modes.  PASSIVE APB records 
an APB Violation and will allow entry or exit.  ACTIVE APB records an APB Violation and will not 
allow entry or exit.  TRAP APB records an APB Violation and will allow entry but not exit. 
 
1. Press 
* 4 3 and enter the four-digit MASTER CODE _ _ _ _ (beep). 
2. Enter 
0 for OFF, 1 for PASSIVE, 2 for ACTIVE or 3 for TRAP, then press * (beep). 
3. Press 
0 # TOGETHER to end this programming step. 
 
3.7.2 Re-Sync 
All 
Devices 
This programming step is used to allow all cards one ‘move’ either in or out without causing an APB 
Violation to be recorded.   
 
1. Press 
* 4 5 and enter the four digit MASTER CODE _ _ _ _ (beep). 
2. Press 
1 to Re-Sync ALL devices or press 0 to not Re-Sync, then press * (beeeeeep). 
3. 
The programming sequence will end itself after all cards are re-synced. 
 
3.7.3 
Re-Sync Individual Devices 
This programming step is used to re-sync a single card only.   
 
1. Press 
* 4 6 and enter the four digit MASTER CODE _ _ _ _ (beep). 
2.  Enter the five digit device number _ _ _ _ _ then press * (beep). 
3. Press 
0 # TOGETHER to end this programming step. 
 
3.7.4 
Reset Facility Counter 
This programming step is used to reset the facility counter.  The facility counter keeps track of the 
number of “IN’s” and “OUT’s” when using APB mode. 
 
1. Press 
* 4 8 and enter the four digit MASTER CODE _ _ _ _ (beep). 
2.  Enter a five digit number that you want the count to start at _ _ _ _ _ then press * (beep). 
(Example: to start at 25, enter 00025) 
3. Press 
0 # TOGETHER to end this programming step. 
 
 
 
 