46
21. Audio Select Set
Function
The external control equipment sets combinations of audio and video inputs
for the plasma monitor.
Transmission Data
DFH
80H
60H
70H
02H
DATA00 DATA01 CKS
DATA00: AUDIO INPUT
01H:
AUDIO 1
02H:
AUDIO 2
03H:
AUDIO 3
DATA01: VISUAL INPUT
01H:
Video 1
02H:
Video 2
03H:
Video 3
05H:
HD (HD1 or DTV or DTV1)
06H:
HD2 (DTV2)
07H:
RGB 1/ PC 1
08H:
RGB 2/ PC 2
0CH:
RGB 3/ PC 3
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH
60H
80H
70H
00H
CKS
* The plasma monitor returns “Not Available” when selecting the
video input same as the one set at one of the AUDIO 01 to 3.
Example:
The plasma monitor returns “Not Available” when selecting the
VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set to
AUDIO1.
22. Audio Select Request
Function
The external control equipment inquires the current combinations of audio
and video inputs for the plasma monitor.
Transmission Data
1FH
80H
60H
6FH
00H
CKS
ACK
The plasma monitor returns the following ACK:
7FH
60H
80H
6FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: AUDIO 1
DATA01: AUDIO 2
DATA02: AUDIO 3
VISUAL INPUT DATA
01H:
Video 1
02H:
Video 2
03H:
Video 3
05H:
HD (HD1 or DTV or DTV 1)
06H:
HD2 (DTV2)
07H:
RGB 1 /PC 1
08H:
RGB 2 /PC 2
0CH:
RGB 3 /PC 3
23. LONG LIFE Set
Function
The external control equipment sets the PLE, ORBITER, and INVERSE (inverse
of image brightness) of the plasma monitor.
Transmission Data
DFH
80H
60H
6BH
03H
DATA00 DATA01 DATA02 CKS
DATA00 : PLE
01H:
AUTO
02H:
LOCK
DATA01 : INVERSE
01H:
ON
02H:
OFF
03H:
WHITE
DATA02 : ORBITER (PICTURE SHIFT)
01H:
ON
02H:
OFF
ACK
The plasma monitor returns the following ACK when setting the PLE, ORBITER,
and INVERSE (inverse of image brightness):
3FH
60H
80H
6BH
00H
CKS
24. Failure Mode Request
Function
The external control equipment inquires the detection of failures of the plasma
monitor.
Transmission Data
1FH
80H
60H
3FH
00H
CKS
ACK
The plasma monitor returns the following ACK:
7FH
60H
80H
3FH
02H
DATA00 DATA01 CKS
DATA00: FAILURE MODE 1
Bit 0 :
PDP MODULE
0: Abnormal
1: Normal
Bit 1 :
1: fixed (backup)
Bit 2 :
TEMPERATURE
0: Abnormal
1: Normal
Bit 3 :
FAN
0: Abnormal
1: Normal
Bit 4 :
1: fixed (backup)
Bit 5 :
1: fixed (backup)
Bit 6 :
1: fixed (backup)
Bit 7 :
1: fixed (backup)
DATA00:FILURE MODE 2
Bit 0–7 : 1: fixed (backup)