5.2.5  Programming a VectorScan, Continued 
13. Press Enter (
) when finished adding PreShots.   The following commands are 
displayed on the bottom of the monitor. 
VectorScan Commands 
E= Edit 
Press + or – key until E is displayed on LCD and press 
Char Select.  Reposition the PTZ and/or change the 
lens settings, then repeat steps 6 and 7. 
D = Delete 
Press + or – key until D is displayed on LCD and press 
Char Select.  The PreShot # entered in step 6 is 
deleted. 
S = Save 
Press + or – key until S is displayed on LCD and press 
Char Select.  The current PTZ and lens (focus and iris) 
settings are saved for the PreShot # entered in step 6. 
14. Press + or – until the character (E, D, or S) for the desired action is displayed on 
the controller LCD and then press Character Select (
ABC
).   
15.  Program another VectorScan or press Clear/Manual (
) to exit the PreShot 
Programming menu. 
5.2.6 Run 
VectorScan 
To run a programmed VectorScan continuously: 
1.  Enter the VectorScan # (0-9) using the numeric keys. 
2. Press 
the 
VectorScan (
) key. 
 
The VectorScan runs continuously until the KD6/HD6 receives another command. 
To run a programmed VectorScan one time through the programmed PreShots: 
1. Press 
the 
Dome Menu (
1. ___
3. ___
) key. 
2. Press 
+ or – until VectorScan Menu is displayed and press Enter (
)
3. Press 
+ or – until Run Once is displayed on the LCD and press Enter (
). 
3.  Enter the VectorScan # (0-9) using the numeric keys. 
4. Press 
Enter (
). 
The dome goes to each programmed PreShot at the velocity programmed and for the 
dwell time specified and then stops. 
Rev. 1.01 
31 900.0800 
  