Инструкция С Настройками для Weber 475

Скачать
Страница из 16
3
3
BUILT-IN CONSTRUCTION GENERAL INFORMATION
WARNING
A Weber-Stephen Products Co. insulated
s l e eve  must  be  used  for  any  bu i l t - i n
installation.
CLEARANCE FROM COMBUSTIBLE SURFACES OR
STRUCTURES
Warning: Clearance from the outside walls of the
sides and back of the insulated sleeve must be a
minimum of 24 inches from a combustible surface.
Measure from the outside wall of the insulated
surface to the combustible surface. Figure 2. Refer 
to “Install Gas Supply” on page 2 before starting
installation.
Figure 2
Figure 1
LOCATING YOUR BARBECUE
When determining a suitable location for your barbecue
installation, give attention to concerns such as exposure
to wind, proximity to traffic paths, and keeping any gas
supply lines as short as possible. Never locate the Weber
Gas Barbecue in a garage, breezeway, shed, under an
unprotected overhang, or other enclosed area. Locate the
barbecue and structure so there is enough room to safely
evacuate the area in case of a fire.
CLEARANCE FROM NON-COMBUSTIBLE SURFACES
OR STRUCTURES
Warning: Clearance from the outside walls of the
sides and back of the insulated sleeve must be a
minimum of 6 inches from a non-combustible surface.
Measure from the outside wall of the insulated
surface to the non-combustible surface . Figure 1.
Refer to “Install Gas Supply” on page 2 before
starting installation.
COMBUSTIBLE SURFACE
24 inches
NON- COMBUSTIBLE SURFACE
6 inches
WARNING: All countertop finished surfaces must be
constructed of a noncombustible material.
WARNING: All countertop finished surfaces must be
constructed of a noncombustible material.
Countertop
Countertop
Insulated sleeve
Insulated sleeve