TROUBLESHOOTING 
 
Problem 
Possible Causes 
Solutions 
The portable air 
conditioner does not 
turn on 
Power failure / outage. 
 
The automatic switch, line 
fuse, or breaker has been 
tripped. 
 
 
 
 
The power supply voltage is 
too low. 
 
The power cord is damaged. 
 
 
 
The L.C.D.I. power plug for the 
unit is tripped. 
 
 
The internal water reservoir is 
full 
and „P1” appears on 
display. 
Restore the power supply. 
 
Flip the switch / change the fuse / turn the 
breaker back on. Also note that you may have 
too many appliances drawing power on one 
circuit, you may need to move the other 
appliances to another circuit. 
 
Move the unit onto another circuit with the 
correct voltage. 
 
Call for service. Only authorized personnel 
should replace damaged power cord or power 
plug. 
 
Press the Reset button on the L.C.D.I. power 
plug. 
 
 
Drain water from the air conditioner. 
The unit turns on but 
the compressor does 
not turn on (the fan 
runs but the unit is not 
cooling) 
The room temperature is 
outside of the operational 
tolerances of the unit. 
 
The Cooling mode is not on. 
 
 
The compressor has not 
turned on yet because of its 
time delay. 
 
The set temperature is too 
high. 
 
 
 
The internal water reservoir is 
full 
and „P1” appears on 
display. 
This unit is designed to work in ambient 
temperatures of 63°F to 90°F. 
 
Press the MODE button until the COOL light 
is shown on the display. 
 
 
Give the compressor 3 minutes to turn on 
after the Cooling mode has been selected. 
 
 
Set the air conditioner to a lower temperature. 
It is recommended to set the temperature to 
at least 5°F of the ambient temperature.  
 
Either manually drain the water by removing 
the drain plug or allow the unit to exhaust the 
water itself by running the fan only mode. 
Then cooling will resume. 
The air coming out of 
the unit is not very 
cold, or the airflow 
volume is weak 
The filters are dirty or 
obstructed. 
 
The air intake or exhaust is 
obstructed. 
 
The unit is set in DRY or FAN 
mode. 
 
Clean the air filters. 
 
Make sure there is at least 20" of clearance 
from the air intake. Make the length of the 
exhaust hose is as short as possible.  
 
Set the unit to the cooling mode.