THEORY OF OPERATION
The Direct Spark Ignition System contains a
Gas Distribution Valve and a Direct Spark Ig-
nition  (DSI)  Control  that  interfaces  with  the
Electronic Oven Control, and spark electrodes.
This provides the direct spark ignition and gas
distribution for Whirlpool self-cleaning gas free-
standing ranges.
A proper ground and the correct polarity is nec-
essary for the DSI control to sense the pres-
INTRODUCTION
ence of a flame. If the polarity is reversed, or
in some cases if there is a poor ground, the
control will appear to operate normally. How-
ever,  after  an  oven  burner  ignites,  the  spark
will  continue  to  occur  at  the  burner,  and  the
valve will then shut off after 4 seconds. This is
because  the  DSI  control  does  not  recognize
the presence of a flame when one is present
(see “Monitoring System,” on page 9).
      Gas Valve /
Ignition Switch
Broil Burner Ignitor
Broil Burner
Gas Distribution Valve
Bake Burner
Bake Burner Ignitor
Ignitor &
Cooktop Burner
Direct Spark
Ignition Control
Gas Distribution Valve