Справочник Пользователя для Bunn Beverage Dispenser CDS-3

Скачать
Страница из 60
48
FIG. 49 TORQUE SENSOR CIRCUIT 
BOARD TERMINALS
P1328
SERVICE (cont.)
TORQUE SENSOR CIRCUIT BOARD
FIG. 48 TORQUE SENSOR CIRCUIT BOARD
P1341
Location:
The torque sensor circuit board is located on the 
rear of the cooling drum mount just left of center.
Test Procedures:
1.  With the ON/OFF switch and Auger switch in the 
“ON” position and the ICE/OFF/NO-ICE switch in 
the “ICE” position check the L.E.D. on the control 
panel.
2.  The L.E.D. for the torque sensor is located between 
the appropriate auger switch and the ice switch.
3.  If the L.E.D. flashes one time every four seconds 
the auger is not turning. If the L.E.D. flashes three 
times every four seconds the torque is less than 
possible. If the L.E.D. flashes four times every four 
seconds the torque is greater than possible.
4.  If the L.E.D. flashes three times every four seconds, 
four times every four seconds or one time every 
four seconds with the auger turning, replace the 
torque sensor circuit board.
Removal and Replacement:
1.  Remove the two #8-32 locking screws securing the 
auger motor cover to the cooling drum mount. 
2.  Remove the cover and set aside for reassembly.
3.  Remove the #8 locking screw on the lower right 
side of the auger motor mounting bracket securing 
the auger motor run capacitor. Set capacitor aside 
with wires attached.
4.  Disconnect the auger motor plug from the connector 
on the main wiring harness.
5.  Remove  the  three  remaining  #8  locking  screws 
securing  the  auger  motor  mounting  bracket  to 
cooling drum mounting bracket.
6.  Remove motor with mounting bracket, drip tray, 
split pin and torsion spring bearings as an assembly 
and set aside for reassembly.
NOTE: When removing or installing the motor be sure 
the split pin in the motor shaft is turned to a position 
that will clear the torque sensor circuit board.
7.   Disconnect the plug from the dispenser main wiring 
harness to the torque sensor circuit board.
8.  Remove the #8-32 locking screw and washer secur-
ing torque sensor circuit board to the cooling drum 
mount.
9.  Remove torque sensor circuit board and discard.
10. Install new torque sensor circuit board in the slot 
in the rear of the cooling drum mount and secure 
with a #8-32 locking screw and washer.
11. Refer to Fig. 49 and reconnect the wires.
12. Reinstall motor with mounting bracket, drip tray, 
split pin and torsion spring bearings using three 
#8 locking screws onto the cooling drum bracket.
13.  
Install the auger motor capacitor on the lower 
right side of the auger mounting bracket using the 
remaining #8 locking screw.
14. Connect the auger motor terminal to the terminal 
on the main wiring harness.
15. Refer to Fig. 49 when reconnecting the wires.
16. Position  the  auger  motor  cover  on  the  cooling 
drum mount and secure with two #8-32 locking 
screws.
27646 122200