Справочник Пользователя для Brother LK3-B448E

Скачать
Страница из 78
47
10. Adjustment
LK3-B448E MARK
II
/BA-16
10-16. Button replacement
10-16-1. Adjustment when the button diameter is changed
Slide base adjustment
1. Adjust the width of the slide base assembly 
w
 to the button width with slide base screw 
e
 so that the bottons
q
 pass smoothly.
The bed slide base assembly 
w
 can be adjusted for button diameters of 9 to 22 mm.
Adjust so that the clearance between the buttons 
q
 and the edge of the slide base assembly 
w
 is 0.5-1.0 mm.
2. There are 3 different button upper covers 
r
. The cover for standard button sizes of 9 to 13 mm is factory
installed.
To attach buttons from 13 to 22 mm in diameter, loosen screw 
t
 and replace cover 
r
 (nonstandard accessories).
3. When the button diameter is changed, adjust button stopper A 
y
 with the adjusting screws 
u
. Adjust until
stopper A 
y
 slides into the groove of the upper cover 
r
 and comes into contact with the second button
(position A).
Button clamp adjustment
1. Loosen step screw 
q
 and insert a button into the button clamp 
w
.
2. Lightly tighten step screw 
q
, and remove the button.
3. Close the button clamp 
w
 opening 0.5 to 1.0 mm using the plate 
e
.
4. Firmly tighten step screw 
q
.
5. After the button is inserted, push the lever 
r
 slightly in the direction of the arrow to check that the trouble
indicator 
t
 does not blink.
* If the indicator blinks, move slightly and narrow the button clamp 
w
 opening (mentioned in 3. above).
0.5mm~1.0mm
AUTO 1
AUTO 2
OFF
BA-1 6
t