Справочник Пользователя для Brother LK3-B448E

Скачать
Страница из 78
65
16. Table of error codes
LK3-B448E MARK
II
/BA-16
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the
wall outlet before opening the face plate of the control box. Touching areas where high voltages are
present can result in severe injury.
Machine motor operation error.
E-13
E-20
E-21
E-30
E-32
E-31
E-40
E-41
E-42
E-50
E-60
E-61
E-62
E-63
E-70
E-80
E-81
E-82
E-90
E-91
Cause
Machine specification select connector is not 
connected properly.
Problem with machine motor stopping, or 
synchronizer connection error.
Data is outside possible sewing area due to 
enlargement ratio setting.
The data format of the user program (% or 
mm) does not match the setting of DIP switch 
A-6.
After changing the setting of DIP switch A-6, clear all 
memory settings. (Refer to “15-1. Clearing all memory 
settings”.)
Stitch pattern data overlaps the sewing area 
when area limiting is active.
Length of a stitch exceeds 10 mm.
Abnormality in the sewing data.
Invalid program number specified.
Needle bar does not stop when the needle is 
raised.
Presser has not been lowered.
Presser cannot be raised.
Presser is not raised.
Presser cannot be lowered.
Cooling fan does not operate.
Motor PROM is not correctly inserted.
Foot switch was depressed when the power 
was turned on.
An operation panel switch was depressed 
when the power was turned on.
Abnormal drop in power supply voltage, or 
power was turned on again immediately after 
it was turned off.
Abnormal rise in power supply voltage.
Remedy
Turn off the power and check if connectors P3 is 
disconnected.
Turn off the power, and then turn the machine pulley to 
check if the machine has locked up. Check the 
synchronizer connection. Check if connectors P11, P12 
and P13 are disconnected.
Turn off the power and check the ground wire 
connection.
Press the RESET switch, and then set the enlargement 
ratio again.
Press the RESET switch, and then reset the memory 
switches “30” and “31” or enlargement ratio.
Press the RESET switch, and then set the enlargement 
ratio again.
If programming a new sewing data, repeat the 
procedure from the beginning.
Press the RESET switch and specify a correct number.
Turn the pulley to align the index mark with the needle 
up stop position. (Refer to “10-12. Adjusting the needle 
up stop position”.) Check the V-belt tension. (Refer to 
“3-18. Installing the V-belt”.)
Refer to “18. Troubleshooting”.
Turn off the power and check the connection of presser 
sensor connector P1.
Turn off the power, and then check if the cooling fan is 
blocked with scraps of thread.
Turn off the power and check.
Turn off the power and check.
Turn off the power and check the operation panel.
 Check that all panel cords are normal.
Turn off the power and check the input voltage. After 
turning off the power, wait 3 seconds or more before 
turning it on again. (Refer to “10-15. Checking the input 
voltage”.)
Turn off the power and check the input voltage. (Refer 
to “10-15. Checking the input voltage”.)
Code
16. Table of error codes
 DANGER
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display
window. Follow the remedy procedure to eliminate the cause of the problem.