Справочник Пользователя для Brother DH4-B980

Скачать
Страница из 66
3. INSTALLATION
RH-9800
8
3-9. Connecting the ground wires and the wirings
1. Connect the foot controller cable (1) and the motor cable (2) to the control box.
2. Install the power switch (3) to the underside of the work table with the two screws (4).
3. Clamp the foot controller cable (1) with the two cable clips (5) and then secure the cable clips (5) with the screws (6).
4. Install the motor cable (2) and the power switch cable to the underside of the work table with the staple (7).
5. Pass the cable and air tube which are coming out of the feed bracket (8) and the left side of the bed stand (9) through
the cable hole (10) in the work table.
6. Pass the cable and air tube which are coming out of the belt cover (11) and the machine head (12) through the cable
hole (13) in the work table.
7. Insert each of the connectors into the connectors on the control box. (Refer to the illustration above.)
8. Pass the cables and air hoses through the two cable holders (14), and then secure the cable holders (14) to the
underside of the work table with the two screws (15).
9. The ground wires (16), (17) should always be connected to the control box.
10. Connect the accessory ground wire (18) to the ground terminal of the control box and to the table leg installation bolt.
Note: If the ground wire is not connected, mis-operation due to discharges of static electricity may occur.
11. Connect the power switch connector (19) to the motor.
1106Q
(2)
(1)
(7)
(3)
(4)
Needle
position sensor
1110Q
1111Q
1108Q
1107Q
1109Q
(9)
(8)
(12)
(11)
(16)
(13)
(10)
(17)
(19)
(10)
(14)
(15)
(15)
(16)
(17)
(18)
4P
12P
6P
6P
6P
White
Blue
Black
White
White
White
(5)
(6)
Power switch installation position
1104Q
1105Q