Flashlight Controls and Functionality
The LED flashlight will automatically turn on in the 
following conditions:
— when the LED flashlight is on the Unit 
  recharging dock and
  •  the AC power is removed;
  •  the LED flashlight is removed from the dock;
  •  the LED flashlight button is pressed.
— when the LED flashlight is removed from the 
  Unit recharging dock and
  •  the LED flashlight button is pressed
To turn off the LED flashlight when the light is ON 
in any condition:
  •  press the LED flashlight button.
NOTE: 
•   We ship the LED flashlight without the batteries 
installed. Carefully install the batteries ensuring 
proper polarity, which is labeled on the LED 
flashlight housing. After installing the UPS and 
turning it on, charge the LED flashlight for at 
least 8 hours prior to use.
•   During the initial charge period, the LED 
flashlight may not function properly due to low 
battery charge.
NOTE: For maximum benefit, install the 
Unit in an easily accessible location so you 
may detach the flashlight for use. Do not 
place anything on top of the Unit that may 
obscure the control panel or flashlight.
A. Connect to AC Utility Power
Plug in the AC cord to a properly grounded wall 
outlet. Please make sure there are no devices 
plugged into the Unit.
B. Charging the Battery
For best results, charge the battery for eight 
hours prior to initial use. The Unit charges 
its battery whenever it is connected to the 
utility power.
C. Plug in Power Devices
Plug your devices into the AC outlets on the 
top of the Unit. To use the Unit as a master 
on/off switch, make sure all of the loads are 
switched on.
Caution: Never connect a laser printer or 
scanner to the backup outlets along with 
other computer equipment. A laser printer 
or scanner draws significantly more power 
when in use than when idle. This may 
overload the Unit.
D. Turning on the Unit
Turn on your Battery Backup by pressing and 
holding the “On/Off” button for longer than two 
seconds until the “AC Power” green light comes 
on. The Unit will beep once.
E. Turning off the Unit
Turn off your Battery Backup by pressing and 
holding the “On/Off” button for more than 
two seconds until the “AC Power” or “Battery 
Power” LED goes off. The Unit will beep once.
F. To Conduct a Self-Test
Use the self-test to verify both the operation 
of the Unit and the condition of the battery. In 
normal utility power, push the “On/Off” button 
for less than 1.5 seconds and the Unit will 
perform a self-test function. During the 
self-test, the Unit operates in backup mode.
NOTE: During the self-test, the Unit briefly 
operates on battery-backup power (the 
“Battery Power” LED comes on). If the Unit 
passes the self-test, it returns to online 
operation. If the Unit fails the self-test, it 
immediately returns to online operation 
and lights the “Replace Battery” LED. The 
loads are not affected. Recharge the battery 
overnight and perform the self-test again. 
If the “Replace Battery” LED is still on, the 
battery needs to be replaced.
G. To Silence Audible Alarm 
While the Unit is in battery-backup mode, push 
the “On/Off” button for less than 1.5 seconds 
to silence the audible alarm. (This does not 
work if the Unit is in a LOW BATTERY or 
OVERLOAD condition.)
All equipment must be powered off prior to 
plugging into the Unit (installation).
Features and Functions
Installation