4
ULTRAGRAPH PRO FBQ1502/ULTRAGRAPH PRO FBQ3102/ULTRAGRAPH PRO FBQ6200
The FBQ1502 requires just one rack space, yet it offers you
tons of effective methods for adjusting the sound characteristics,
and is ultra-compact and extremely simple to operate.
The  FBQ3102  features  31  frequency  bands  per  channel  as
well as adjustable high-pass and low-pass filters. These filters
further augment the adjustability options available to you.
With its integrated limiters, noise generator and the adjustable
subwoofer  output  with  signal  level  display  and  its  62  lighted
45 mm faders, the FBQ6200 is our top model in this category.
Future-oriented  BEHRINGER  technology
To  assure  the  highest  possible  degree  of  usability,  all  our
equipment  is  manufactured  adhering  to  the  highest  quality
standards  in  the  audio  industry.  Your  equalizer  has  been
manufactured under ISO9000 certified management system.
Relay-controlled  hard  bypass
The  so-called  hard  bypass  relays  were  integrated  into  the
development concept of the FBQ6200 and the FBQ3102. These
relays assure that your equalizer is automatically switched into
bypass  mode  in  the  event  of  loss  of  power  or  faulty  power
delivery. These fail-safe relays also produce a slight delay during
powering up in order to avoid dangerous switch-on thumps.
Balanced  inputs  and  outputs
The BEHRINGER ULTRAGRAPH PRO models feature electronic
servo-balanced inputs and outputs. The servo function performs
automatically,  recognizing  when  unbalanced  signals  are
connected  and  internally  converts  the  nominal  signal  level  so
that no signal level difference between input and output signals
occurs  (6  dB  correction).
+
The  following  user’s  manual  is  intended  to
familiarize  you  with  the  unit’s  control  elements,  so
that  you  can  master  all  the  functions.  After  having
thoroughly  read  the  user’s  manual,  store  it  at  a  safe
place  for  future  reference.
1.1 Before you get started
1.1.1 Shipment
The ULTRAGRAPH PRO was carefully packed at the factory
to assure secure transport. Should the condition of the cardboard
box suggest that damage may have taken place, please inspect
the unit immediately and look for physical indications of damage.
+
Damaged units should NEVER be sent directly to us.
Please  inform  the  dealer  from  whom  you  acquired
the  unit  immediately  as  well  as  the  transportation
company  from  which  you  took  delivery  of  the  unit.
Otherwise,  all  claims  for  replacement/repair  may
be  rendered  invalid.
1.1.2 Initial operation
Please make sure the unit is provided with sufficient ventilation,
and never place the ULTRAGRAPH PRO on top of an amplifier or
in the vicinity of a heater to avoid the risk of overheating.
+
Before plugging the unit into a power socket, please
make  sure  you  have  selected  the  correct  voltage:
The  fuse  compartment  near  the  power  plug  socket  contains
three  triangular  markings.  Two  of  these  triangles  are  opposite
one another. The voltage indicated adjacent to these markings is
the  voltage  to  which  your  unit  has  been  set  up,  and  can  be
altered by rotating the fuse compartment by 180°. ATTENTION:
This  does  not  apply  to  export  models  that  were  for
example  manufactured  only  for  use  with  120  V!
+
If  you  alter  the  unit’s  voltage,  you  must  change  the
fuse  accordingly.  The  correct  value  of  the  fuse
needed  can  be  found  in  the  chapter
“SPECIFICATIONS”.
+
Faulty  fuses  must  be  replaced  with  fuses  of
appropriate  rating  without  exception!  The  correct
value of the fuse needed can be found in the chapter
“SPECIFICATIONS”.
Power  is  delivered  via  the  cable  provided  with  the  unit.  All
requiered safety precautions have been adhered to.
+
Please  make  sure  that  the  unit  is  grounded  at  all
times.  For  your  own  protection,  you  should  never
tamper  with  the  grounding  of  the  cable  or  the  unit
itself.
1.1.3 Warranty
Please take a few minutes and send us the completely filled
out warranty card within 14 days of the date of purchase. You
may also register online at www.behringer.com. The serial number
needed  for  the  registration  is  located  on  the  rear  of  the  unit.
Failure to register your product may void future warranty claims.
1.2 The user’s manual
The user’s manual is designed to give you both an overview of
the control elements, as well as detailed information on how to
use them. In order to help you understand the links between the
controls,  we  have  arranged  them  in  groups  according  to  their
function.  Should  you  need  detailed  information  about  specific
topics  not  covered  in  this  manual,  please  visit  our  website  at
www.behringer.com. For example, additional information about
power  amps  and  effects  processors  is  found  there.
2. CONTROL ELEMENTS AND
CONNECTORS
2.1 Front panel
In  this  chapter  we  will  describe  various  control  elements  of
your  equalizer.  All  controls  and  connectors  are  explained  in
detail,  and  you  will  also  find  useful  hints  on  how  to  best  use
them.  Since  the  three  equalizers  in  the  FBQ  series  are  fairly
similar, let’s start with the control elements of the FBQ1502 and
the FBQ3102 that are similar to the control elements found on the
FBQ6200.  The  FBQ6200  additionally  features  extra  control
elements that will be explained in detail later on.
The INPUT/OUTPUT LEVEL METER lets you keep an eye
on the signal level in order to avoid distortion. Depending
on the position of the I/O METER IN/OUT switch
, the
display shows either the input or the output signal (switch
depressed)  level.  When  the  signal  level  reaches  roughly
+18 dB, that is, 3 dB below clipping starts to occur, the red
CLIP LED lights up.
The level meter on the FBQ1502 displays only the output
signal level.
+
Attention:  extreme  frequency  boosts  in  connection
with a high input signal level may lead to overdriving
your  equipment.  Should  this  occur,  it  is  necessary
to  reduce  the  input  signal  level  by  using  the  INPUT
control.
2. CONTROL ELEMENTS AND CONNECTORS