6. OPERATION
RH-981A
44
6-5. Production counter
1.  Press the SELECT key (1) to change the mode to automatic mode.
2.  Press the   key and    key simultaneously.
* "PC" will flash in the program number display (2), and the production counter value will appear in the detail
display (3).
3.
Press the          keys to change the production counter setting.
*  The production counter setting will flash while the setting is being changed.
* If you would like to set the production counter to "0", press the RESET key (4).
4.
Press the ENTER key (5). The production counter value will be accepted and the mode will return to automatic
mode.
* If you press the SELECT key (1) while the production counter value is still flashing, the mode will return to
automatic mode without the production counter value being changed.
6-6. Using the program memos
Insert the program memos (1) into the rear of the
operation box (2) for safekeeping.
Program memo contents
1. Easy reference guide
2. Error code table
3. Parameter table
4. Program notes
Use a lead pencil to make any additions to the
parameter table and for writing anything into the
program notes. If you do so, additions can be removed
using an eraser and the space can be re-used. The
program notes are useful for recording what patterns
have been entered into which programs.
3053Q
3054Q