Power Fail.  Optional.  Enter the power fail report number if a report has been created (see
applicable ACU manual). The report states the actions that will be taken by the ACU should
a power failure occur.  Default is 0.

Override.  Optional.  Enter the operator override report number if a report has been created
(see applicable ACU manual). The report states the actions that will be taken by the ACU if,
for example, a manual unlock or a shunt occurs.  Default is 0.
 
Type.  Optional.  Enter the number for the key type used.  Default is 0.
N
OTE
The valid key types are as follows:
0 — None
1 — 1030
2 — 1040
3 — 1050
4 — 1060
5 — 1050 / 1060 / Digital Keys
5
Aux. Type.  Conditional.  Auxiliary key type.  A second key type, other than the one entered
in the previous field, can be entered here if applicable.  Default is 0.
0 — None
1 — 1030
2 — 1040
Note: the previous two fields are applicable only to devices that support multiple key types.
6
Facility.  Required for key types 1 and 2 (previous field).  Enter the facility code assigned to
the keys.  Defaults to **** if omitted.
7
Alt Facility.  Conditional.  Enter a second facility code to allow a different set of keys to be
used with this ACU.  Defaults to **** if omitted.
9
Auto Forgive.  Optional.  Up to four time codes can be entered that execute the forgive
command at the ACU.  Default is 0 (feature disabled if all auto-forgive time codes are 0).
:;
808 Modem Definition.  Not used.
Number of Retry Times.  Not used.
:>
XON/XOFF.  Not used.