PILOT GAS CONNECTION
Install fitting into pilot gas outlet (see figure 3), turning until
finger-tight. Insert clean, deburred tubing all the way through the
fitting. While holding the tubing securely, slowly tighten fitting
until you feel a slight "give". Tighten the fitting an additional 1½
turns.
INSTALLATION
Pilot gas
outlet
Gas outlet
  
PILOT
  
PRESS
  
TAP
Figure 3
Figure 4
GREEN
WHITE
RED
4
2
TAN
TAN
TAN
PRESSURE
SWITCH
REDUNDANT
COIL
RELAY COIL
NOTE
All wiring should be installed in accordance with local and
national electrical codes and ordinances.
Always check that the electrical power supply used agrees
with the voltage and frequency shown on the gas control.
REFER TO AND FOLLOW THE APPLIANCE MANUFACT-
URER'S WIRING DIAGRAM. USE THE TABLE ON PAGE 1
TO IDENTIFY THE PROPER TERMINAL IDENTIFICATION
FIGURE FOR THE GAS VALVE.
SYSTEM WIRING
Wiring for 36C84-926, -936 & 36C94-907 Gas Valves
24 VAC
THERMOSTAT
LIMIT
LINE
5022 
SAFETY
TIMER
PILOT/REDUNDANT 
SOLENOID VALVE
MAIN VALVE RELAY
36C84 GAS VALVE
C
S
3098 MERCURY
FLAME SENSOR
HOT
COLD
3
2
4
PRESSURE
SWITCH
WIRING
HARNESS
N.O.
Cycle Pilot System
- For All Gases -
RESISTOR
DIODE
SCR
A
C
G
WARP SWITCH
HEATER
WARP
SWITCH
BLUE
RED
TAN
YELLOW
ORANGE
1
3
4
2
5
T1
T2
4
5
3
2
6
5059
Pilot
Relight
Control
  
F115-0055
12 in.
F115-0056
18 in.
F115-0057
24 in.
F115-0058
30 in.
F115-0059
36 in.
Type Number
Length
Wiring Harness Available
For All Gases
Wiring Harness consists of five wire 
cable in black sheathing. One end 
terminated in five-terminal connector 
for mating to 5022 or 50A22. Other 
end terminated with six terminal 
connector to mate with gas manifold.
24 VAC
THERMOSTAT
LIMIT
LINE
PILOT/REDUNDANT 
SOLENOID VALVE
MAIN VALVE RELAY
36C84 GAS VALVE
C
S
3098 MERCURY
FLAME SENSOR
HOT
COLD
3
2
4
PRESSURE
SWITCH
WIRING
HARNESS
N.O.
Cycle Pilot System
- For Natural Gas -
T1
T2
4
5
3
2
6
5059
Pilot
Relight
Control
  
F115-0060
12 in.
F115-0061
18 in.
F115-0062
24 in.
F115-0063
30 in.
F115-0064
36 in.
Type Number
Length
Wiring Harness Available
For Natural Gas
Wiring Harness consists of two wires, 
one tan the other black. Both leads 
are terminated with 1/4 inch female 