E Series Built-In Double Ovens
Installation Notes
Wolf E Series built-in ovens may be used in
a standard installation, where the face trim
overlaps stiles and rails, or in a flush inset
installation with the front of the oven flush
with surrounding cabinetry.
Complete installation specifications can be
found on our website, wolfappliance.com.
Unit dimensions may vary by ±
1
/
8
".
 
 5" 
(127) 
28
1
/
2
(724) 
OPENING WIDTH 
4" 
(102) 
33" 
(838) 
RECOMMENDED CABINET WIDTH 
30"
min (762) 
 
49
5
/
8
(1260) 
OPENING 
HEIGHT 
24"
min (610) 
OPENING DEPTH 
 
 
67"
typical
(1702)
ELECTRICAL LOCATION 
WITHIN OPENING 
APPLIES ONLY TO  
CABINETS DEEPER 
THAN 24" (610) 
Specifications
Overall Width
29
7
/
8
"
Overall Height
50
3
/
8
"
Overall Depth
23
3
/
4
Oven Door Clearance
22" 
Oven Interior Capacity
(per oven)
4.5 cu ft
Oven Interior Dimensions
(per oven)
25" W x 16
1
/
2
" H x 19" D
Recommended Cabinet Width Standard  30"
Flush Inset  33"
Minimum Cabinet Depth
Standard  24"
Flush Inset  25"
Minimum Base Support
400 lbs
Opening Width
28
1
/
2
"
Min Inset Width
30
3
/
8
"
Opening Height
49
5
/
8
"
Min Inset Height
50
15
/
16
"
Electrical Requirements
240/208 V AC
60 Hz, 50 amp circuit
Electrical Rating
8.9 kW at 240 V
6.7 kW at 208 V
Shipping Weight
466 lbs
Installation
Specifications
Standard Installation
Overall Dimensions
IMPORTANT NOTE: Unless you are using cabinets
deeper than 24" (610) for a standard installation or
25" (635) for a flush inset installation, it is recom-
mended that the electrical supply be placed in an
adjacent cabinet within reach of the conduit.
Choose the location shown in the illustrations that
best suits your installation.
23
3
/
4
(603)
BEHIND FRAME
50
3
/
8
"
(1280)
49
1
/
2
"
(1257)
28
1
/
4
"
(718)
29
7
/
8
"
(759)
23
3
/
4
"
(603)
OPEN OVEN DOOR
TOP VIEW
2
5
/
8
"
(67)
22"
(559)
1
1
/
4
"
(32)
1" 
(25)
1
7
/
8
"
(48)
1
7
/
8
"
(48)
RIGHT SIDE VIEW
29
7
/
8
"
(759)
INSTALLER
SUPPLIED CABLE
CHANNEL
49
5
/
8
"
(1260)
OPENING
HEIGHT
50
15
/
16
"
min (1294)
FLUSH
INSET
HEIGHT
30
3
/
8
"
min (772)
FLUSH INSET WIDTH
28
1
/
2
(724)
OPENING WIDTH
 5"
(127)
4"
(102)
E
E
E
E
36" 
(914)
RECOMMENDED CABINET WIDTH
33"
min (838)
24"
min
(610)
OPENING
DEPTH
1" 
(25)
25"
min
(635)
FLUSH
INSET
DEPTH
7
/
16
(11)
7
/
8
(22)
ELECTRICAL LOCATION
WITHIN OPENING
APPLIES ONLY TO 
CABINETS DEEPER
THAN 25" (635)
67"
typical
(1702)
SIDE VIEW
TOP VIEW
Flush Inset 
Installation
Dimensions in
parentheses are in 
millimeters unless