iPump 6420 User’s Manual
 
www.wegener.com 
800070-01 Rev B 
Chapter 2, Page 26 
 
2.3. Equipment 
Setup 
2.3.1. 
iPump 6420 Rear Panel Connections 
Before applying power, make the following connections, as necessary, to your 
iPump 6240
. For 
connector details, refer to Table 2-1Error! Reference source not found..  For help deciding which 
connectors and signals to use, consult Chapter 3. 
1)  Connect the L-band output from your antenna's LNB to your 
iPump 6240
's input RF port, 
OR
, if 
supplied with ASI Input interface, connect a coax cable to your ASI Transport source (such as 
another satellite IRD).Connect your balanced analog audio ports (1, 2, or 3 [Aux]) to your 
analog audio distribution system (DA). 
Or
 connect the AES3 digital audio outputs (for 1 & 2 
only) to your digital audio distribution system (DA). 
2)   Connect a CAT5 cable from the 
iPump 6240
's LAN port to the desired LAN segment in order to 
access the 
iPump 6240
's web control screen.  If that LAN segment can reach the internet, then this 
may be the only adaptor needed (see next). 
3)  If you wish to have your iPump 6420 be able to send Return Path over internet to the uplink 
control system, then the LAN segment connected to the LAN port must be allowed to make 
outbound HTTP connections, and you must protect the iPump 6420 from inbound 
connections from the internet.  If so, then you may skip the next step
. 
4)  Connect a CAT5 cable from the 
iPump 6240
's WAN port to an external broadband internet 
connection.  Remember, this is used only for connections unprotected by NAT router and/or 
firewall.  
5)  Connect the Modem jack to a local analog phone line, if using Return Path, but where the 
Ethernet adaptors cannot be wired to have access to the internet. 
6)  Connect one of more of your 
iPump 6240
 Cue Relays ports to the local commercial insertion 
equipment (if used). 
7)  Connect one or more of your iPump 6420 RBDS output ports to the radio station exciter’s 
RBDS input, if supporting RBDS distribution in this radio network. 
8)  Connect one or more of your iPump 6420 AM/FM tuner inputs to appropriate radio antenna, 
if supplied and using Off-Air Recording audits.  You must be using Return Path to support 
return transmission of recorded OAR files.
 
9)  Connect the local automation systems’s relay closure outputs to the PIO Input connector. 
10) For diagnostics, you may connect a text-based monitor to the Serial M&C port. 
11) Connect the Alarm port to downstream redundancy control or alarm monitoring system. 
12) Connect the supplied ac power cord to the 
iPump 6240
's IEC receptacle and then to a  
100-to-120 VAC or 200-to-240 VAC source. 
Once all of the ports are connected and power is 
supplied, the iPump 6240 
begins the startup process and will require about 2 ½ minutes to 
complete.