PART NO. 37-6658D
Replaces 37-6658C
0927
36H UNIVERSAL GAS VALVES
FIELD
CONVERSION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE 
INSTALLING  OR  OPERATING  THIS  CONTROL  COULD  CAUSE  PERSONAL 
INJURY AND/OR PROPERTY DAMAGE.
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
DESCRIPTION
The 36H universal gas valves are designed for use on automatic 
spark ignition systems. The valves are shipped from the factory 
set for natural gas non-piloted applications. See the Installation 
Instructions included with the valves for proper installation.
This document shows the modifications required if the valve is 
to be installed on an LP gas and/or piloted gas application.
LP GAS CONVERSION
For  LP  gas  conversion,  use  the  LP  conversion  kit  supplied 
separately with this control. Refer to the instructions packed 
separately with LP conversion kit.
PILOTED GAS APPLICATIONS
WIRING
These valves are shipped with an external wire jumper installed 
for non-piloted gas applications. For applications requiring piloted 
gas, such as intermittent pilot or spark-to-pilot systems, remove 
the external wire jumper from the main (M) and pilot (P) valve 
terminals (see figure 1).
Refer to the 36H Series Installation Instructions for additional 
system wiring information.
PILOT GAS CONNECTION
These gas valves are shipped with the pilot outlet plugged. For 
installations requiring pilot gas, remove the plug from the pilot 
gas outlet (see figure 2) and use the fitting packed separately 
with the valve.
Install the fitting into the pilot gas outlet, turning until finger tight. 
Insert clean, de-burred ¼” O.D. tubing all the way through the 
fitting. While holding the tubing securely, slowly tighten the fit-
ting until you feel a slight “give”. Tighten the fitting an additional 
1-1/2 turns.
The plug should not be removed for a Direct Burner Ignition 
system such as Direct Spark or Hot Surface Ignition.
Refer to the 36H Series Installation Instructions for pilot flame 
adjustment information.
Pilot Gas
Outlet
Outlet
Pressure
Tap
Main Gas
Outlet
Figure 2.  Gas valve outlet end
 
Model 
No.  
Opening 
 
No. 
of Stages 
Characteristics
  36H32-XXX 
Fast
  36H33-XXX 
Slow
  36H64-XXX 
Fast
  36H65-XXX 
Slow
PILOT (REDUNDANT)
EXTERNAL 
JUMPER
2ND 
STAGE
TWO STAGE
MODELS ONLY
(+)
(-)
SW1
SW1
SW2
P
MAIN
C
SW2
RECTIFIER
(-)
RECTIFIER
(+)
M
RECTIFIER
(-)
(+)
HI
Figure 1.  Gas valve internal wiring and terminal
identification 