Справочник Пользователя для Vogelzang International Stove TR008

Скачать
Страница из 22
TR008 / 050207.2 
DURANGO™ / 
Page 
READ ALL INSTRUCTIONS CAREFULLY 
BEFORE STARTING THE INSTALLATION  
OR OPERATING THE STOVE. FAILURE TO 
FOLLOw INSTRUCTIONS mAY RESULT  
IN PROPERTY DAmAGE, BODILY INjURY, 
OR EVEN DEATH.
DO 
NOT USE THIS STOVE IN A  
mOBILE HOmE, mANUFACTURED HOmE, 
TRAILER OR TENT — NO EXCEPTIONS!
This stove meets  
Test Standards:
UL 1482-1996 U.S.
SAFETY INSTRUCTIONS
SAFETY  NOTICE:  IF THIS  STOVE  IS  NOT  PROPERLY  INSTALLED  A  HOUSE/BUILDING  FIRE 
mAY  RESULT.  FOR YOUR  SAFETY,  CONTACT  LOCAL  BUILDING  OR  FIRE  OFFICIALS  ABOUT   
PERmITS, RESTRICTIONS, AND INSTALLATION REqUIREmENTS FOR YOUR AREA.
Read all InstRuctIons caRefully.
1.  The installation of this stove must comply 
with your local building code rulings. Please 
observe the clearances to combustibles (see 
Locating Stove). Do not place furniture or 
other objects within the clearance area.
2.  Verify  that  the  stove  is  properly  installed 
before  firing  the  stove  for  the  first  time. 
After reading these instructions, if you have 
any  doubt  about  your  ability  to  complete 
your  installation  properly,  you  must  ob-
tain the services of a professional licensed 
installer  familiar  with  all  aspects  of  safe 
  and  correct  installation.  DO  NOT  use  
temporary  or  makeshift  compromises  
during installation.
3.  DO NOT store wood, flammable liquids or 
other combustible materials too close to the 
unit. Refer to certification label on back of 
unit and minimum clearances under Locat-
ing Stove in the following instructions.
4.  Do  not  install  this  stove  in  a  mobile 
home,  manufactured  home,  trailer  or  tent  
(NO  EXCEPTIONS!  per  HUD  Federal  
Standard: 24 CFR Ch.XX).
5.  If any parts are missing or defective, please 
notify the dealer or manufacturer immediately. 
DO  NOT  OPERATE A  STOVE  THAT  IS 
MISSING ANY PARTS!.
6.  Do  not  tamper  with  combustion  air  control 
beyond normal adjustment capacities.
7.  Always connect this stove to a chimney and 
vent to the outside. Never vent to another room 
or  inside  a  building.  DO  NOT  CONNECT 
THIS UNIT TO A CHIMNEY FLUE SERV-
ING ANOTHER APPLIANCE.
8.  DO NOT CONNECT a wood burning stove 
to  an  aluminum  Type  B  gas  vent.  This  is 
not  safe.  Use  approved  masonry  or  a  UL 
103  HT  Listed  Residential Type  and  Build-
ing  Heating Appliance  Chimney.  Use  a  6” 
diameter  chimney,  that  is  high  enough  to 
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
THE DURANGO
 HiGH  
EfficiENcy WOODsTOvE
EPA Certified (3.6 grams/hr)
model TR008 
Owners manual
(save this manual for future reference)
continued on next page