Configuring the AP
92
AP-4131 Access Point Product Reference Guide
2.6.2 128-Bit 
WEP 
Encryption
Select 128-bit from the Key Width field of the WEP Encryption Configuration 
screen, and select the Encryption Key Maintenance option to display the 
Encryption Key Maintenance screen.
Symbol Access Point
                           Encryption Key Maintenance
                     PassKey      ********************
                      .Key 1   *  00000 00000 0000 0000 0000 0000
                      .Key 2      00000 00000 0000 0000 0000 0000
                      .Key 3      00000 00000 0000 0000 0000 0000
                      .Key 4      00000 00000 0000 0000 0000 0000
 
                                  * = Active Key
   Note: This screen has Write-Only access. Keys can be set but not displayed. Zeros 
         are displayed to indicate the field sizes. A line containing all zeros allows
         the corresponding key to remain unchanged.
    OK-[CR]       Save-[F1]      Save All APs-[F2]         Cancel-[ESC]
Each key has 104-bits available to the user for configuration and are 
displayed in two 20-bit segments and four 16-bit segments. The remaining 
24 IV (initialization vector) bits are factory set and not user configurable.
1. Enter a PassKey (optional) as a plain text representation of the WEP keys 
in the Encryption Key Maintenance screen. 
The access point transforms the PassKey string into set of 4 WEP keys 
using MD5 algorithms. When <Enter> is pressed, the WEP keys appear 
in the WEP key fields and are the active keys. Once the keys appear in 
the WEP fields, the screen behaves as if the keys were entered manually. 
Pressing [F1] saves the keys to flash (keys remain active) and pressing 
[ESC] discards the keys. 
The PassKey provides an easy way to enter WEP key data without having 
to remember the entire 40-bit (10 character) or 128-bit (26 character) 
Hex digit string.