Справочник Пользователя для Symbol Technologies Spectrum24 AP-4131

Скачать
Страница из 250
Monitoring Statistics
186
AP-4131 Access Point Product Reference Guide
3.10 Event History
The AP tracks specific events. The types of events logged are configurable. 
The log is a 128-entry circular buffer. After the 128th entry, the earliest event 
entry deletes.
The Event History displays the most recent event at the top of the list. Each 
event lists a time stamp recorded in hh:mm:ss from the time the AP powered 
up or reset. The type of event logged follows the time stamp. If the event 
involves an MU or AP, the unit MAC address displays.
Symbol Access Point              Event History                           pg 2
       Warning: Event logging is frozen while this screen is displayed.
               0:07:44  MU Assoc 00:A0:F8:12:59:C3
               0:06:42  Telnet Session Start From 111.111.12.169
               0:06:00  Telnet Session End
               0:01:51  MU Assoc 00:A0:F8:12:59:E8
               0:01:38  MU Assoc 00:A0:F8:12:59:9B
               0:01:38  MU Assoc 00:A0:F8:12:5A:05
               0:00:42  Telnet Session Start From 111.111.12.169
               0:00:10  WLAP Assoc 00:A0:F8:8A:30:77
               0:00:10  MU Assoc 00:A0:F8:12:59:C3
               0:00:02  RF Initialized
               0:00:00  Ethernet Initialized
               0:00:00  Multitasker Initialized
               0:00:00  AP Driver Initialized
               0:00:00  Event Log Initialized
           Previous-[F3]          Next-[F4]           Exit-[ESC]