F100 – Network Port Configuration & XLi Firmware
F100 provides two groups of commands:
•
Group 1, available through the keypad/display and the command line, provides access to
network port settings and hardware/Firmware status information.
•
Group 2, available through the command line only, provides commands for changing system
firmware, changing SNMP parameters, changing the user name/password, resetting the unit,
and pinging other network devices.
and pinging other network devices.
Warning: The F100 commands have the capacity to remove the XLi from the network and disable the
XLi’s system firmware. Use judiciously.
XLi’s system firmware. Use judiciously.
Reboot Warning: Saving changes to any F100 parameter using the keypad/display will reboot the XLi.
Some of the F100 command line commands also reboot the XLi. These are identified in the following
documentation.
Some of the F100 command line commands also reboot the XLi. These are identified in the following
documentation.
Group 1
You can use both the keypad/display and the command line interface to access the following
parameters:
parameters:
•
Ethernet address: XLi contains a unique Ethernet or Media Access Control (MAC) address
comprised of a unique number assigned to the manufacturer, and a unique number assigned to
the unit. This is factory set and cannot be changed.
the unit. This is factory set and cannot be changed.
•
IP Address: Sets a static Internet Protocol (IP) address for the unit.
•
Subnet Mask: Sets a valid subnet-mask used in IP addressing. Subnetting allows for the more
efficient allocation of network addresses and management of network traffic.
•
Default Gateway: The address of the router that handles packets addressed to IP devices
outside the local-area network.
•
10 100 BASE-T: The network port bandwidth setting, 10 Base-T or AUTO. (10 Base-T only for
earlier XLi hardware).
•
Remote Lockout: Enables or disables remote access through the XLi’s standard network port.
Enabling Remote Lockout limits users to the front-panel keypad or Serial I/O port.
•
Flash CRC: Status - Passed or failed.
•
RAM: Status - Passed or failed.
•
Serial: Status - Passed or failed.
•
Version Test: Status - Passed or failed