Instruction Manual
78
    port attached. In 
Applicable Hosts, check the IP address/DNS  
    name of the IIS server. 
Click 
13. 
Connection Alert.
Click 
14. 
Apply.
Now, you can set the console server to send alerts to the Nagios server. 
Lastly you need to add a User for the client running MetaConnect: 
Select 
1. 
Users & Groups from the Serial & Network menu. 
Click 
2. 
Add User.
In Username, enter: sdtnagiosuser, then enter and confirm a Password. 
3. 
In 
4. 
Accessible Hosts click the IP address/DNS name of the IIS server,  
  and in 
Accessible Ports click the serial port that has the router  
  console port attached 
Click 
5. 
Apply.
Enable Nagios on the ECS0016
Select 
1. 
System: Nagios on the ECS0016 Management Console and  
  select 
Nagios service Enabled. 
Enter the 
2. 
Nagios Host Name that the ECS0016 gateway will be  
  referred to in the Nagios central server – this will be generated from  
  local System Name (entered in System: Administration) if unspecified 
In Nagios Host Address enter the IP address or DNS name that the  
3. 
Remote 
ECS0016 
Gateway