VU-Cal
The display range of the VU meter can be shifted using the -10dB 
VU Cal switch position.
If the VU Cal switch is set to its 0 dB position and the output 
level control is also set to 0dB with the limiter switched off, 
the output level will effectively be 0 dBu. With the VU Cal set to 
-10 dB the 0 dB mark on the VU meter will represent a +10 dBu 
output level. This way you can display audio level higher than 
+6 dB (up to +16 dB) on the VU meter.
Source
This switch allows you to select between the Mic and Line/
Instrument inputs. All inputs can remain connected at all times, 
regardless of which input is selected. You can choose the Line 
input as source as long as the Instrument Input is not being 
used.
If you engage this switch first after powering up the unit, there 
can be a noticeable pop due to the discharge of residual current. 
This is normal and no cause for concern.
Central Display
The display consists of all status LEDs and the VU meter so that 
all important information can be viewed without distraction.
Display/VU Meter
The VU meter shows the internal gain level (not the output 
level). Its scale ranges from -20 dB to +6 dB. If needed, the sensi-
tivity can be reduced by 10 dB, which extends the scale to +16 dB  
(see “VU Cal“ above). Please refer as well to the information 
“About Gain Adjustments” on page 10.