Operating Humidity Range 
0-85% Relative Humidity 
Electrical 
Voltage 
120VAC +/- 10%, Split, Single Phase 
240VAC +/- 10%, Single Phase 
277VAC +/- 10% Three Phase 
Frequency 
60Hz 
Maximum Load 
20 Amps;1800 Watts (for incandescent loads) 
Load Type(s) 
Wired-in incandescent lighting and inductive loads 
Retains all settings without power 
Yes, all saved in Non-volatile EEPROM 
Standby power consumption 
< 1 watt 
Safety Approved 
ETL (Intertek Testing Services) 
Certifications 
FCC, IC Canada 
X10 Features (applies to power line only) 
X10 Primary Address 
X10 Status Response  
Supported 
X10 Powerline Frequency 
120 KHz 
X10 Messages Repeated 
No 
 
 
Troubleshooting
 
Problem 
Possible Cause 
Solution 
The Status LED on In-
LineLinc is not turning 
on and won’t control 
the load.  
In-LineLinc may not be 
getting power.  
Make sure the circuit breaker is turned on. 
Check the junction box wires to ensure all 
connections are tight and no bare wires are 
exposed. 
In-LineLinc won’t link 
or work with a 
controller.  
The controller might have 
been reset without 
Unlinking In-LineLinc from 
it.  
Re-Link In-LineLinc to the controller. 
The INSTEON signal may 
be too weak. 
Add additional INSTEON devices or move around 
existing INSTEON devices. All INSTEON devices 
act as INSTEON network repeaters.  
Large appliances, such as 
refrigerators or air 
conditioners, may be 
producing electrical noise 
on the power line.  
Install a power line noise filter (#1626-10) to filter 
electrical noise and minimize signal attenuation.