Note:
- Each zone can program up to 2 sensors.  There are 5 zones, so up to 10 sensors
  can be programmed to the control panel.  Please refer to page 37, "Sensor
  Location Selection Guide" for detail information.
Alert Mode Examples  (Door/Window sensor sold separately)
Note:
-For Door / Window sensor, alert notification (beeping and LED flashing) will
 continue until the sensor is in closed position, i.e. closing the window or door.
-For Motion Sensor, the alert notification (beeping and LED flashing) will last for 20
 seconds for every detected movement.
The Control Panel is always in one of the 2 operating modes:
1. Alert Mode - When the system is not armed (ARM LED off), it is in alert mode.
2. Alarm Mode - When the system is armed (ARM LED on), it is in alarm mode.
The Control Panel will be in alert mode automatically if the system is not armed.
Alert mode allows users inside the premises to know what sensor is triggered.
It is intended to be used when someone stays inside the premises.
In alert mode, the control panel will give you notification of the triggered sensor(s)
by voice announcement, unique beeping and LED flashing.
1
Number of beeps
Zone of the triggered sensor
2
Number of flashes of zone LED
Sensor number of the triggered sensor
3
Voice announcement
Tells you the zone and locations of
the triggered sensor by human voice.
Alert Mode
3. Double flash
1.
Zone 3
Sensor 2
Triggered
3. Single flash
1.
Zone 1
Sensor 1
Triggered
2.
Beep___Beep___
Beep___Beep .....
Zone 1 Sensor 1
          door open
Zone 3 Sensor 2  window
                               open
2.
Beep Beep Beep___
Beep Beep Beep___
18
ADVANCED PROGRAMMING
Zone 1
SENSOR 1
Button [1]
SENSOR 2
Zone 2
Zone 3
Zone 4
Zone 5
Button [2]
Button [3]
Button [4]
Button [5]
Button [6]
Button [7]
Button [8]
Button [9]
Button [0]
This row
:
Buttons for
Sensor 1
Zone LED :
Flash once
This row
:
Buttons for
Sensor 2
Zone LED :
Flash twice
Erase Sensors
Proceed to the following to erase a sensor.
1
2
3
[PROG]
[MPIN]
Enter
Programming
mode
Enter master
password to
programming mode
3  beeps for valid password.
1 long beep for invalid
password.
[9]
Select erase
remote
programming
After [9] is entered, some
zone LEDs will flash or
stay off.  The zone LEDs
represent whether that zone
is occupied by any sensor.
**See Table D below.
Refer to the table
below to select the
remote location.
Select the
sensor you
would like to
erase
After you have  selected the
sensor, you will hear 3 beeps
and verbal confirmation
[Zone X Sensor Y Empty
Memory], where X and  Y
are the zone and sensor
numbers you have  selected.
To erase an
occupied
sensor, press
[1] to [0].
ZONE LED
DESCRIPTION
Off
Zone is not occupied by any sensor
Flashes once
This zone is occupied by sensor 1.
Flashes twice
This zone is occupied by sensor 2.
Flashes once,
This zone is occupied by sensors 1 and 2.
then twice
** Table D: Zone LED status for erasing sensors.
Step
Keys
Function
Description
Note
®
39