Справочник Пользователя для Simrad AP25

Скачать
Страница из 172
Simrad AP25 Autopilot 
128
 
20221495F
 
        
 
 
Autotrim standard value is 40 sec. which should work well on 
most boats.  
Rudder Limit should be kept at 20 degrees unless there is a 
need for more rudder when performing dockside manoeuvres.  
Recall Autotuned? 
 
To recall the parameter values 
that were achieved during the 
Automatic tuning procedure, 
rotate the course knob 
clockwise. When parameter 
values are recalled, Confirmed 
is displayed. 
Exit the Parameter menu by pressing STBD button to proceed to 
the Service menu, or press STBY to return to normal AP25 
operation. 
4.9 
Service Menu 
Select STANDBY mode and then enter the Installation Menu by 
pressing and holding the INFO/SETUP button for 5 seconds. 
Select "SERVICE" by pressing the STBD button and confirm by 
rotating the course knob clockwise. 
 
System data and NMEA data 
are test functions to analyze 
data processed by the AP25. 
Sn 00000 is the unique 
SimNet ID number for the 
specific autopilot control unit. 
To exit the menu, press any 
mode key (STBY, AUTO or 
NAV). 
Correct setting of counter 
rudder, ideal response 
New course