Справочник Пользователя для Simrad AP25

Скачать
Страница из 172
Simrad AP25 Autopilot 
48
 
20221495F
 
2.22  Multiple station system 
In normal operation control is accessible from every control unit 
connected to the AP25 system. One control unit is "active" and 
provides the user with access to all functions. All remaining 
control units are "inactive" and have no effect on mode changes 
or course selection. A single press on any of the mode buttons on 
an "inactive" control unit will allow transfer of command and 
make it "active". 
 
2.23  Lock function 
The "LOCK" function is a safety feature in the AP25 system. It 
will disable all control units, including the FU25 Follow-up 
lever, except for a single user selected control unit location. 
When the "lock" function is in use, no transfer of command can 
take place; only the active control unit stays in command. 
To enable the "lock" function, make a quick double press on the 
STBY button. 
 
 
The display on the active control unit will first show a   icon 
and then the icon will alternate with the mode index. 
The "locked" control units in the system will show: