Инструкции По Обслуживанию для Sigma Gold TDP-52-SN3

Скачать
Страница из 183
27.1.1999 
Xo0236e4_fm5.fm
18
Product: DB-40 (Branching Unit) /      YO0236
9.2.2.3 Connector PC Signals
9.2.3 Operation
Audio routes for either an external handset or a line converter are selected 
using audio switches I201 (mic) and I202 (erp). The operation is controlled by 
the HOOK data coming from the XHSERP line. OFF HOOK audio signals have 
been routed to connector HS, and ON HOOK audio signals to connector PC. 
Voltage regulation is done by components R205, C207 and D201.
1 and 2
V-CHARGE
Battery charging voltage 2 A in
3
9V
Operation voltage for accessories 0.5 A out
5
PCMIC
Ext audio from microphone1 kHz / 400 
mVrms
6 and 7
GND
Ground
8
PCERP
Ext audio for loudspeaker amplifier 1 kHz / 
200 mVrms
10
I2CINT
I2c interruption, input to radio 0/5 V
11
SCL
I2c clock 0/5 V
12
SDA
I2c data 0/5 V
13
TXD
Rs232 0/5 V out
14
RXD
Rs232 0/5 V in
16
CHCGONT
Voltage for controlling charger current 0...5 
VDC analog