DV425TR DIRECT VENT ROOM HEATER
02/01                                                                                     Page 19                                                                               250-5533
Four types of direct vent system installations are 
approved for use with the DV425TR.  
1.  Horizontal Termination (Fig. 1, page 22)
2.  Vertical Termination (Fig. 2, page 23)
3.  Into a Class A Metal Chimney (Fig. 3, page 24) 
USA installations only
4.  Into a Masonry Chimney (Fig. 4, page 25) USA 
installations only
Do not connect to a chimney serving a separate solid-
fuel burning appliance.
In each of these installation methods, it is very important 
to  maintain  a  balance  between  the  combustion  air 
intake and the flue gas exhaust venting system.  
Note:   Certain  limitations  as  to  vent  and  vertical 
termination configurations apply, and must be strictly 
adhered to. 
When  planning  your  installation,  it  is  necessary  to 
select the proper length of vent pipe for your particular 
requirements. 
1.    For  installations  with  any  horizontal  vent  run  or 
horizontal termination, refer to the Vent Graph on page 
27.   This  graph  will  show  the  relationship  between 
vertical and horizontal side wall venting, and help you 
to  determine  the  amount  of  vertical  rise  necessary 
for “vertical-to-horizontal” type installations. NOTE:  Be 
sure to take into consideration the wall thickness when 
calculating your venting needs. 
2.  To determine the length of pipe required for vertical 
installations, measure the distance from the stove flue 
outlet to the ceiling, the ceiling thickness, the vertical 
rise in an attic or second story, and allow for sufficient 
vent  height  above  the  roofline.  Refer  to  the  vertical 
vent termination tables on page 35 for this information.  
For  two-story  applications,  fire  stops  are  required  at 
each  floor  level.  If  an  offset  is  needed  in  the  attic, 
additional  pipe  and  elbows  will  be  required.   When 
INSTALLATION METHODS & NOTES
determining  the  position  of  the  stove,  be  sure  to 
adhere to minimum clearance to combustibles to the 
appliance itself. (See page 8, Minimum Clearances to 
Combustibles.)
3.    When  installing  this  appliance  into  an  existing 
masonry chimney, it is important to carefully measure 
the length of flex needed to reach from the appliance 
outlet to the termination cap. If the flex length is too 
short,  a  flex  coupler  will  be  needed  to  attach  an 
additional length of flex liner to make up the difference. 
If the flex length is too long, the liner could sag below 
the appliance outlet, which could result in an airflow 
restriction causing flow reversal or flame lift. 
SAFETY PRECAUTIONS FOR THE INSTALLER
Wear  gloves  and  safety  glasses  for  protection  when 
installing  this  stove. Exercise  extreme  caution  when 
using  ladders  or  on  rooftops  around  power  lines. 
Be  aware  of  electrical  wiring  locations  in  walls  and 
ceilings.
!! IMPORTANT !!
INSERT TOP GRILL ONTO STOVE
 
TOP 
PRIOR
 TO COMPLETING 
VENTING INSTALLATION !!