Справочник Пользователя для Sapphire Audio DV425TR

Скачать
Страница из 60
DV425TR DIRECT VENT ROOM HEATER
02/01                                                                                     Page 49                                                                               250-5533
In Canada, this unit is approved from 0 to 4500 
feet above sea level. Installation of this stove at 
altitudes above 4500 feet is subject to field test of 
the individual installation and approval by the local 
authority having jurisdiction.
In the United States, input ratings of this unit are 
based on sea level operation, and shall not be 
changed for operation at elevations up to 2000 feet. 
For operation at elevations above 2000 feet, this 
stove shall be reduced at the rate of 4% for each 
1000 feet above sea level.
Exception:  As permitted by the authority having 
jurisdiction.  
To adjust stove for operation above 2000 feet the 
burner orifice may need to be changed.  The orifice 
is located beneath the logset so it is necessary to 
first remove the logs.  To do so please refer to the 
following  detailed instructions  to achieve optimum 
performance of your stove.
Equivalent burner orifice sizes at high altitudes
(Includes 4% Input Reduction For Each 1000 Feet)
HIGH ALTITUDE OPERATION
CAUTION:  DISCONNECT ANY ELECTRICAL 
CORDS AND TURN OFF GAS SUPPLY TO 
UNIT BEFORE PROCEEDING.
WARNING ! The following procedure 
should only be undertaken by a qualified 
and certified gas appliance installer.
1.  Remove front (if installed), glass, and logs (if 
installed.)
 2.  Remove log/burner pan: First remove screws 
then lift the front of pan vertically and slide pan to 
one side and pull out of firebox. See page 12.
 3.  Remove burner plate.
 4.  Remove main burner orifice using a 5/8" wrench.
 5.  Replace orifice with the proper size as indicated 
in the chart below for your gas type and venting 
installation. 
 6.  Re-install burner plate:  First slide burner tube 
into shutter and over holes.  Secure plate with 
screws.
 7.  Re-install log/burner pan. Slide vertically into the 
back of firebox and then place horizontal onto 
burner plate.  
8.  Install logs, refer to page 14 for correct place-
ment.
9.  Replace glass door and front.
 
ALTITUDE
0-2000  3000 
4000 
5000 
6000 
7000 
8000 
9000 
10000
TOP VENT: 
Natural Gas 
 
36(.106) 36(.106) 37(.104) 38(.101) 39(.099) 40(.098) 40(.095) 41(.096) 41(.096) 
Propane 
 
52(.063) 52(.063) 52(.063) 53(.059) 53(.059) 53(.059) 54(.055) 54(.055) 54(.055)
REAR VENT:
Natural Gas 
 
41(.096) 41(.096) 42(.093) 43(.089) 44(.086) 44(.086) 45(.082) 45(.082) 46(.081)
 
Propane 
 
53(.059) 53(.059) 53(.059) 54(.055) 54(.055) 54(.055) 55(.052) 55(.052) 55(.052)