Справочник Пользователя для Robertshaw 9620

Скачать
Страница из 14
TABLE 1
Old Terminal
New Label
Description
R, V-VR or VR-R
R
24 VAC 
Y, Y1 or M
Y1
Stage 1 Cooling/Heating Circuit
O or R
O
Reversing Valve (Cooling Mode)
B
B
Reversing Valve (Heating Mode)
G or F
G
Fan Contactor Circuit
Y2
Y2
2nd Stage Cooling Circuit
W1 or W2 or W-U
W2
2nd Stage Heating Circuit
L or X
L
System Monitor LED
E
E
Emergency Heating Circuit
C, X or B
C
24 VAC Transformer Common Side
NOTE: T
HIS THERMOSTAT REQUIRES A
24V AC 
COMMON WIRE FOR PROPER OPERATION
.
5. After labeling wires, remove wires from terminals.
6. Remove existing thermostat base from wall.
7. Refer to the following section for instructions on how to 
install thermostat.
Recycling Thermostat
If this thermostat is replacing a thermostat that contains mercury in a
sealed tube, do not place your old thermostat in the garbage. Contact your
local waste management authority for instructions regarding proper dis-
posal of the thermostat. If you have any questions, call Robertshaw tech-
nical support at 1-800-445-8299.
Step 2: Installing Model 9620 Thermostat
NOTE: F
OR NEW INSTALLATIONS
MOUNT THERMOSTAT ON INSIDE WALL
, 4-5 
FEET ABOVE THE FLOOR
. D
O NOT INSTALL
BEHIND A DOOR
IN A CORNER
NEAR AIR VENTS
IN DIRECT SUNLIGHT
OR NEAR ANY HEAT OR STEAM GENERATING FIX
-
TURES
. I
NSTALLATION AT THESE PLACES WILL AFFECT THERMOSTAT OPERATION
.
IMPORTANT: T
HIS THERMOSTAT IS COMPATIBLE WITH
100% 
LOCKOUT SYSTEMS
. T
O RESET THE SYSTEM
TURN
THERMOSTAT TO
OFF 
POSITION FOR AT LEAST
60 
SECONDS
.
1. Turn off power to the heating and cooling systems.
2. Place COOL-OFF-HEAT-EM in OFF position.
3
PROG
MAN
SET PROG/MAN
COOL-OFF-HEAT-EM
AUX
CHECK EMER
  AUTO - ON
>
>
AUTO - ON
COOL-OFF-HEAT-EM