Техническое Описание для Rinnai ES38 (RHFE-1004FTA)
ES38 (RHFE-1004FTA)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us
Safety Devices
Venting
Maximum Vent Length
Wall Thickness and
Flue Manifold Kits
(the “A” vent kit is included
with the appliance)
Flue Manifold Kits
(the “A” vent kit is included
with the appliance)
Warranty
Conversion Kits
• Flame rod detects flame failure; results in auto shutdown to prevent escape
of gas
• Bi-metal switch, thermal fuse, and thermistor detect overheat condition;
results in auto shutdown
• 5 amp fuse protects against power surge; results in auto shutdown
• Abnormal spark at time of ignition results in auto shutdown
• Combustion fan purges any gas from the combustion chamber before
• Abnormal spark at time of ignition results in auto shutdown
• Combustion fan purges any gas from the combustion chamber before
ignition
• Convection fan continues to run after burner shutdown to cool internal parts
• Function lock prevents inadvertent operation
• Appliance shuts down if room reaches 104° F (40° C)
• Function lock prevents inadvertent operation
• Appliance shuts down if room reaches 104° F (40° C)
concentric; 3 1/8 inch (80 mm) wall hole
13 feet (4 m) with a maximum of 2 bends
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years
Available for conversion to natural gas (204000026) or propane (204000027)
DIMENSIONS
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Name
Kit No.
fits walls
S Vent Kit
FOT-150
3 - 4 1/2 in (75 - 115 mm)
A Vent Kit
FOT-151
4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit
FOT-152
9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit
FOT-153
15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit
FOT-154
23 5/8 - 31 1/2 in (600 - 800 mm)