O P E R A T I O N
Options Window
350-9047 v3.0.1
DGy Model 201x User’s Guide
53
. . . . .
G A M M A
Use this adjustment when the replay device has a different 
gamma than that of the recorded image. An example would be 
between a CRT and an LCD monitor. The range is from 0.5 to 2 
in increments of 0.05. 
T I M I N G   L I S T
When the output 
Mode
 is set to 
Freerun
, use the 
Timing List 
section of the 
Output
 tab to set the output format. Select the 
required format from the drop down 
Timing List 
and click on the 
Load
 button. 
The timing parameters associated with the format selected from 
the 
Timing List
 are displayed in the 
Video Output Timing 
section 
of the 
Output
 tab. Click the 
Edit
 box to make changes to the 
parameters. Modified settings may then be saved to the 
Timing 
List 
by selecting an unused entry in the list, between 100 and 
160, and clicking the 
Save
 button. Unwanted entries to the 
Timing List
 can be deleted by selecting an entry and clicking 
Delete
To return to the default autosync mode, set the output 
Mode
 to 
Playback
.
V I D E O   O U T P U T   T I M I N G
Output timing parameters are displayed for the timing selected 
from the 
Timing List
. These parameters may be edited checking 
the 
Edit
 box. 
See 
 on page 49 for more 
information on timing parameters.
S Y N C   T Y P E
Select the synchronization parameters as required.
S C A N   R A T E
Set the 
Scan Rate
 parameters as required.
Note
The gamma of the input image recorded to disk is 
preserved. The 
Gamma
 control does not apply to the 
input image.
Important
Changing timing parameters should be done by 
experienced video engineers only.