Справочник Пользователя для Promise Technology VTrak J610s

Скачать
Страница из 62
Chapter 3: Management
37
The system returns:
 -------------------------------------------------------------------------------------
Time Since Power Up: 1 day 9 hours 46 minutes 36 seconds
Enclosure: SAS JBOD [2U-12Bay or 3U-16 Bay]
I/O Module ID: 1
Max Num Of I/O Modules: 2
FwVersion: 1.07.0000.00
I/O Module Role: Primary
MaxNumOfHDSlots: [12 or 16] MaxNumOfPSUs: 2
MaxNumOfFans: 4
MaxNumOfBlowers: 2
MaxNumOfTempSensors: 8
MaxNumOfVoltageSensors: 5 
===========================================
PSU
Status
Fan1Speed
Fan2Speed
===========================================
1
Operational
14735 rpm
15037 rpm
2
Operational
15340 rpm
14361 rpm
===========================================
Blower Status
Speed
===========================================
1
Operational
4017 rpm
2
Operational
4066 rpm
===========================================
ID Location
Temp Reading
ID Location
Temp Reading
===========================================
1. Backplane
27C/80F
2. Backplane
28C/82F
3. Backplane
26C/78F
4. Backplane
26C/78F
5. I/O Module1 35C/95F
6. I/O Module1 26C/78F
7.
I/O Module2 33C/91F
8. I/O Module2 38C/100F
Thermal Management: Enabled
Allows to shut down the system when critical temperature is reached: Yes
Current minimum fan speed setting: medium low
Enclosure Temp Threshold: 61C/141F (critical) 51C/123F (warning)
Controller Temp Threshold: 71C/159F (critical) 61C/141F (warning)
===========================================
VoltageSensor
Voltage
===========================================
1
3.3V
2
5.0V
3
5.0V
4
12.0V
5
1.1V