Справочник Пользователя для Pentax Home Gym R-322(N)

Скачать
Страница из 52
PSF Software Ver.365 
 
22 
 
 
 
 
At the procedure 6, the 00" of the DEVIATE.value can be easily got if the minimum count is set to 1 ".   
 
At the procedure 8, a prism can be easily tracked if a position is searched using the [TRACK] function 
and then using the [MEAS] function. 
 
 
  (2) Search and Call of the stored Foresight Point Number 
 
1
 
 
Move the cursor to 3. STAKEOUT 
 
 
 
 
 
 
 
 
             
     COORD.STAKEOUT 
2
 
 
Press the [ENT] key. 
 
 
 
 
 
 
 
 
           
       
FORESIGHT NUMBER LIST 
Search for the desired Foresight point number
 
4
 
 
Confirm the called Foresight Coordinates 
and press [ENT] key. If the prism height 
change is necessary, press the [ENT] key 
after the change. 
 
 
 
 
 
       ANGLE COMPARE 
1. JOB NAME 
2. STATION SET UP 
3. STAKEOUT
 
1. 0000               
2. 1234 
3. 0025
                                     
DESIGN     90°  00'  00" 
H.angle       0°  00'  00" 
DEVIATE.   - 90°  00'  00" 
 
 
          H.INPUT 0 SET
 
ANG/DIST